Influence of Perspective Distortion in Laryngoscopy.

J Speech Lang Hear Res

University Hospital Erlangen, Medical School, Division of Phoniatrics and Pediatric Audiology at the Department of Otorhinolaryngology Head and Neck Surgery, Friedrich-Alexander-University Erlangen-Nürnberg, Germany.

Published: September 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: An experiment with controllable boundaries was designed to assess the influence of the recording angle and distance on two-dimensional (2D) imaging in laryngoscopy and resulting 2D parameter calculation derived from the glottal area waveform (GAW).

Method: Two high-speed camera setups were used to synchronously record an oscillating synthetic vocal fold (VF) model, simulating a high-speed videoendoscopy. One camera recorded at variable lateral recording angles and a reference camera in superior perspective. This was performed at different physiological recording distances and for two oscillation modes (with/without contacting VFs). The GAW was derived from the segmented glottis, and two parameters each for the categories of symmetry, periodicity, and closure were calculated, as well as two derivative measures. The percentage difference between the variable and reference camera value pairs was calculated, and the angle and height dependencies were quantified using linear regression.

Results: The visual perception of a laryngoscopy was found to be influenced by the lateral recording angle, which may lead to misinterpretation of VF symmetry among inexperienced observers. The strongest influence of recording angle was observed for symmetry parameters, the strongest being the Amplitude Symmetry Index with up to 2.6%/° ( < .05). A dependence on the recording distance was only found for the Maximum Area Declination Rate.

Conclusions: The recording angle in 2D laryngoscopy should be carefully considered during visual inspection of the VF dynamics. Most of the investigated objective parameters were unaffected by the examined perspective distortion. However, especially left-right symmetry measures should only be used under controlled boundary conditions to avoid misdiagnosis and misinterpretation.

Supplemental Material: https://doi.org/10.23641/asha.23961183.

Download full-text PDF

Source
http://dx.doi.org/10.1044/2023_JSLHR-23-00027DOI Listing

Publication Analysis

Top Keywords

recording angle
16
perspective distortion
8
influence recording
8
lateral recording
8
reference camera
8
recording
7
angle
5
symmetry
5
influence perspective
4
laryngoscopy
4

Similar Publications

Sustainable bio-based film based on chitosan resin crosslinking with tannin, phytic acid and octadecylamine for food packaging application.

Int J Biol Macromol

September 2025

Yunnan Provincial Key Laboratory of Wood Adhesives and Glued Products, Southwest Forestry University, Kunming 650224, People's Republic of China. Electronic address:

Chitosan and tannin are both promising renewable materials for food packaging; however, their effectiveness is limited by incomplete interactions between them. Therefore, phytic acid and octadecylamine were employed to create chitosan-tannin-phytic acid-octadecylamine (CTPO) films that are flame-retardant, UV-resistant, antibacterial and hydrophobic for food packaging applications. The findings indicate that the CTPO film exhibited excellent hydrophobicity and mechanical properties, with a water contact angle of 133.

View Article and Find Full Text PDF

Purpose: To assess the clinical outcomes of Hydrus Microstent implantation with cataract extraction for the treatment of open angle glaucoma (OAG) over a maximum of 4 years.

Design: Retrospective, single-center, single-arm, longitudinal cohort study.

Subjects: 308 patients (464 eyes) with OAG who underwent Hydrus Microstent implantation with cataract extraction between February 2019 and December 2021, followed for a median (interquartile range, IQR) of 2.

View Article and Find Full Text PDF

The aim of this study was to compare the compressive forces generated by Dynamic Compression Angle-Stable Interlocking Nail (DCASIN) with those of traditional Dynamic Compression Plates (DCP) and Locking Compression Plates (LCP) using synthetic diaphyseal bone models (SDBM). Three groups were established based on the fixation method (G-DCASIN, G-DCP, and G-LCP), with implants fixed to SDBM simulating a transverse fracture, comprising 10 repetitions per group. A strain-gauge load cell was positioned in the SDBM gap to measure compressive forces in kilograms, recorded 30 s after the completion of each group-specific compression technique.

View Article and Find Full Text PDF

It is unknown how knee osteoarthritis pain affects joint power distribution while cycling. The study purposes were to (1) investigate if seat height, workload and any difference in hip or knee extensor strength affected asymmetry of hip, knee and ankle joint power during cycling; and (2) determine the relationship between knee osteoarthritis pain asymmetry and joint power asymmetry at the hips, knees, ankles and total leg. Asymmetry was the difference between dominant and non-dominant legs.

View Article and Find Full Text PDF

Aim: Patients undergoing maintenance hemodialysis (MHD) often have multiple comorbidities and are vulnerable to minor stressors that frequently result in hospitalization. Recent advances have enabled the easy estimation of body composition in clinical settings. This study retrospectively investigated changes in body composition associated with hospitalization in patients receiving MHD.

View Article and Find Full Text PDF