A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Evaluation of different algorithms for automatic segmentation of head-and-neck lymph nodes on CT images. | LitMetric

Evaluation of different algorithms for automatic segmentation of head-and-neck lymph nodes on CT images.

Radiother Oncol

Centre Léon Bérard, 28 rue Laennec, LYON 69373 Cedex 08, France; CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, Villeurbanne, France. Electronic address:

Published: November 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To investigate the performance of 4 atlas-based (multi-ABAS) and 2 deep learning (DL) solutions for head-and-neck (HN) elective nodes (CTVn) automatic segmentation (AS) on CT images.

Material And Methods: Bilateral CTVn levels of 69 HN cancer patients were delineated on contrast-enhanced planning CT. Ten and 49 patients were used for atlas library and for training a mono-centric DL model, respectively. The remaining 20 patients were used for testing. Additionally, three commercial multi-ABAS methods and one commercial multi-centric DL solution were investigated. Quantitative evaluation was assessed using volumetric Dice Similarity Coefficient (DSC) and 95-percentile Hausdorff distance (HD). Blind evaluation was performed for 3 solutions by 4 physicians. One recorded the time needed for manual corrections. A dosimetric study was finally conducted using automated planning.

Results: Overall DL solutions had better DSC and HD results than multi-ABAS methods. No statistically significant difference was found between the 2 DL solutions. However, the contours provided by multi-centric DL solution were preferred by all physicians and were also faster to correct (1.1 min vs 4.17 min, on average). Manual corrections for multi-ABAS contours took on average 6.52 min Overall, decreased contour accuracy was observed from CTVn2 to CTVn3 and to CTVn4. Using the AS contours in treatment planning resulted in underdosage of the elective target volume.

Conclusion: Among all methods, the multi-centric DL method showed the highest delineation accuracy and was better rated by experts. Manual corrections remain necessary to avoid elective target underdosage. Finally, AS contours help reducing the workload of manual delineation task.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radonc.2023.109870DOI Listing

Publication Analysis

Top Keywords

manual corrections
12
automatic segmentation
8
multi-abas methods
8
multi-centric solution
8
elective target
8
evaluation algorithms
4
algorithms automatic
4
segmentation head-and-neck
4
head-and-neck lymph
4
lymph nodes
4

Similar Publications