A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Preliminary Assessment of Reference Region Quantification and Reduced Scanning Times for [F]SynVesT-1 PET in Parkinson's Disease. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Synaptic density in the central nervous system can be measured using PET with [F]SynVesT-1. While [F]SynVesT-1 has been proven to be a powerful radiopharmaceutical for PET imaging of neurodegenerative disorders such as Parkinson's disease (PD), its currently validated acquisition and quantification protocols are invasive and technically challenging in these populations due to the arterial sampling and relatively long scanning times. The objectives of this work were to evaluate a noninvasive (reference tissue) quantification method for [F]SynVesT-1 in PD patients and to determine the minimum scan time necessary for accurate quantification. [F]SynVesT-1 PET scans were acquired in 5 patients with PD and 3 healthy control subjects for 120 min with arterial blood sampling. Quantification was performed using the one-tissue compartment model (1TCM) with arterial input function, as well as with the simplified reference tissue model (SRTM) to estimate binding potential (BP) using centrum semiovale (CS) as a reference region. The SRTM2 method was used with ' fixed to either a sample average value (0.037 min) or a value estimated first through coupled fitting across regions for each participant. Direct SRTM estimation and the Logan reference region graphical method were also evaluated. There were no significant group differences in CS volume, radiotracer uptake, or efflux ( > 0.47). Each fitting method produced BP estimates in close agreement with those derived from the 1TCM (subject s > 0.98, bias < 10%), with no difference in bias between the control and PD groups. With SRTM2, BP estimates from truncated scan data as short as 80 min produced values in excellent agreement with the data from the full 120 min scans (bias < 6%). While these are preliminary results from a small sample of patients with PD ( = 5), this work suggests that accurate synaptic density quantification may be performed without blood sampling and with scan time under 90 minutes. If further validated, these simplified procedures for [F]SynVesT-1 PET quantification can facilitate its application as a clinical research imaging technology and allow for larger study samples and include a broader scope of patients including those with neurodegenerative diseases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10445483PMC
http://dx.doi.org/10.1155/2023/1855985DOI Listing

Publication Analysis

Top Keywords

reference region
12
[f]synvest-1 pet
12
scanning times
8
parkinson's disease
8
synaptic density
8
reference tissue
8
scan time
8
blood sampling
8
quantification performed
8
quantification
7

Similar Publications