Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: During fractional flow reserve (FFR) measurements, distal coronary pressure (Pd) can be influenced by hydrostatic pressure changes resulting from the height difference (HD) between the coronary ostium and the location of the distal pressure sensor.

Aims: We investigated the effect of aortocoronary HD on the FFR measurements in each coronary artery.

Methods: In this retrospective cohort study, we analyzed 257 patients who underwent FFR measurements and coronary computed tomography (CCTA) within a year. Using CCTA, we measured HD as the vertical distance between the coronary ostium and a matched point of the distal coronary pressure sensor identified on coronary angiography.

Results: The location of the Pd sensor was higher than the coronary ostium in the left anterior descending artery (LAD) (-4.64 ± 1.15 cm) and lower than the coronary ostium in the left circumflex artery (LCX) (2.54 ± 1.05 cm) and right coronary artery (RCA) (2.03 ± 1.28 cm). The corrected FFR values by HD were higher in the LAD (0.78 ± 0.09 to 0.82 ± 0.09, P<0.01) and lower in the LCX and RCA than the original FFR values (0.87 ± 0.07 to 0.85 ± 0.08, P<0.01; 0.87 ± 0.10 to 0.86 ± 0.10, P<0.01, respectively). Using an FFR cut-off value of 0.8, the concordance rates between the FFR and corrected FFR values were 77.8%, 95.2%, and 100% in the LAD, LCX, and RCA, respectively.

Conclusion: HD between the coronary ostium and the distal coronary pressure sensor may affect FFR measurements and FFR-guided treatment decisions for coronary artery disease.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10449150PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0289646PLOS

Publication Analysis

Top Keywords

coronary ostium
20
ffr measurements
12
coronary
11
height difference
8
difference coronary
8
ostium location
8
pressure sensor
8
fractional flow
8
flow reserve
8
distal coronary
8

Similar Publications

Single coronary ostium and intramural coronary artery variations in patients with transposition of the great arteries significantly increase the mortality and morbidity after arterial switch operation (ASO). In these patients, the classic coronary button implantation may cause kinking or twisting of the coronary artery which can cause coronary insufficiency. This case series presents two patients, a 15-month-old girl with transposition of the great arteries and a 10-month-old boy with a Taussig-Bing anomaly.

View Article and Find Full Text PDF

Background: Percutaneous coronary intervention (PCI) with drug-eluting stents (DES) on ostial left circumflex (oLCx) is associated with a high rate of adverse events.

Aims: This study aims to compare drug-coated balloons (DCB) and DES in the treatment of oLCx lesions.

Methods: Consecutive patients undergoing DCB-PCI of de novo oLCx lesions (isolated or in the context of a distal left main bifurcation) in eight international centers from 2018 to 2023 were retrospectively enrolled and compared with a historical cohort of patients who received PCI with DES.

View Article and Find Full Text PDF

Background: Mounting evidence suggests surgical left atrial appendage (LAA) exclusion reduces stroke risk in patients with atrial fibrillation. Prior older research suggests that LAA exclusion is often incomplete, but few transesophageal echocardiogram (TEE) data exist evaluating LAA remnants.

Methods: We analyzed 121 patients with an available postoperative TEE who underwent LAA exclusion by surgical excision (SE), AtriClip occlusion (AO), or Tiger Paw occlusion (TO).

View Article and Find Full Text PDF

Purpose: The morphological and functional characteristics and clinical significance of the left atrial appendage (LAA) are well established in patients with non-valvular atrial fibrillation (AF). However, data on the LAA characteristics in patients with mitral valve (MV) disease are limited. This study aimed to identify the LAA characteristics in AF patients with severe MV disease.

View Article and Find Full Text PDF

Fluoroscopy-free ablation techniques have gained popularity in recent years. However, coronary sinus (CS) cannulation via the femoral approach remains technically challenging, particularly when using specialized catheters like the BeeAT™. To demonstrate a reproducible technique for fluoroscopy-free CS cannulation using the BeeAT catheter guided by CARTO® electroanatomical mapping and intracardiac echocardiography (ICE).

View Article and Find Full Text PDF