A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Environmentally friendly stability-indicating HPLC method for the determination of isotretinoin in commercial products and solubility samples. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In this study, an environmentally friendly "high-performance liquid chromatography (HPLC)" assay to quantify isotretinoin (ITN) in commercial products and solubility samples is designed and verified. A Nucleodur reverse-phase C column was used as the stationary phase to identify ITN. The ecologically friendly mobile phase was composed of ethyl acetate and ethanol (50:50 v/v), and it was delivered at a flow rate of 1.0 mL/min. ITN was measured at 354 nm in wavelength. The current HPLC method had a determination coefficient of 0.9994 and was linear in the 0.2-80 μg/g range. The current protocol for ITN measurement was also rapid (retention time = 2.78 min), accurate (%recoveries = 98.60-101.52), precise (% uncertainties = 0.71-0.98), and sensitive. According to the AGREE methodology, the current procedure received an outstanding greenness profile with an AGREE score of 0.76. By determining ITN in commercial products and solubility samples, the applicability of the current approach was proven. ITN was discovered to be present in 98.43% and 100.84%, respectively, of commercial capsule brands A and B. The ITN's solubility in numerous eco-friendly solvents was successfully measured. Under different stress conditions, the current approach was able to distinguish between its degradation products, demonstrating its stability-indicating characteristics. These findings indicated that ITN in procured capsules and solubility samples might be regularly tested by the suggested approach.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10412884PMC
http://dx.doi.org/10.1016/j.heliyon.2023.e18405DOI Listing

Publication Analysis

Top Keywords

solubility samples
16
commercial products
12
products solubility
12
environmentally friendly
8
hplc method
8
method determination
8
itn commercial
8
current approach
8
itn
7
solubility
5

Similar Publications