A Method for Measuring Parameters of Defective Ellipse Based on Vision.

Sensors (Basel)

Center of Ultra-Precision Optoelectronic Instrument, Harbin Institute of Technology, Harbin 150080, China.

Published: July 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Ellipse detection has a very wide range of applications in the field of object detection, especially in the geometric size detection of inclined microporous parts. However, due to the processing methods applied to the parts, there are certain defects in the features. The existing ellipse detection methods do not meet the needs of rapid detection due to the problems of false detection and time consumption. This article proposes a method of quickly obtaining defective ellipse parameters based on vision. It mainly uses the approximation principle of circles to repair defective circles, then combines this with morphological processing to obtain effective edge points, and finally uses the least squares method to obtain elliptical parameters. By simulating the computer-generated images, the results demonstrate that the center fitting error of the simulated defect ellipses with major and minor axes of 600 and 400 pixels is less than 1 pixel, the major and minor axis fitting error is less than 3 pixels, and the tilt angle fitting error is less than 0.1°. Further, experimental verification was conducted on the engine injection hole. The measurement results show that the surface size deviation was less than 0.01 mm and the angle error was less than 0.15°, which means the parameters of defective ellipses can obtained quickly and effectively. It is thus suitable for engineering applications, and can provide visual guidance for the precise measurement of fiber probes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10384787PMC
http://dx.doi.org/10.3390/s23146433DOI Listing

Publication Analysis

Top Keywords

fitting error
12
parameters defective
8
defective ellipse
8
based vision
8
ellipse detection
8
major minor
8
detection
6
method measuring
4
parameters
4
measuring parameters
4

Similar Publications

In ultrasound imaging, propagation of an acoustic wavefront through heterogeneous media causes phase aberrations that degrade the coherence of the reflected wavefront, leading to reduced image resolution and contrast. Adaptive imaging techniques attempt to correct this phase aberration and restore coherence, leading to improved focusing of the image. We propose an autofocusing paradigm for aberration correction in ultrasound imaging by fitting an acoustic velocity field to pressure measurements, via optimization of the common midpoint phase error (CMPE), using a straight-ray wave propagation model for beamforming in diffusely scattering media.

View Article and Find Full Text PDF

Accurate estimation of individual feed intake is essential for calculating feed efficiency, planning diets, monitoring cow herds, and managing grazing cows. This study aimed to evaluate the performance and applicability of estimation equations developed to predict pasture herbage DMI (PHDMI) in dairy cows using behavioral traits recorded and scored by the RumiWatch system. The study had 4 primary objectives: (1) to compare the behavioral characteristic outputs of 2 versions of the RumiWatch converter (0.

View Article and Find Full Text PDF

Purpose: To achieve spectrally resolved in vivo detection of glutamate, glutamine, and glutathione at 3 T.

Methods: Difference editing of N-acetylaspartate CH protons (NAA-CH) combined with a new echo-time (TE) optimization approach is introduced. Difference editing was used to detect NAA-CH independently of NAA-CH, thereby eliminating systematic errors arising from constrained fitting of the entire NAA molecule.

View Article and Find Full Text PDF

Liquid chromatography has advanced considerably since its introduction in the 1970s, with reversed-phase liquid chromatography (RPLC) becoming the dominant technique for separating non-volatile molecules. A key strategy for optimising separation conditions is the modelling of chromatographic retention from experimental data. Traditionally, this is achieved by fitting model parameters for each solute, resulting in individual solute models (ISMs).

View Article and Find Full Text PDF

Albumin and γ-globulin concentrations in an electrolyte solution have been quantified by a multivariate-regressive Gaussian admittance relaxation times distribution (mgARTD). The mgARTD is built based on the training data consisting of the impedance spectroscopy system measurement result of protein mixture solutions with a known concentration of albumin, γ-globulin, and sodium electrolyte to perform concentration quantification on a prospective protein mixture solution with an unknown concentration. The mgARTD consists of three steps: (1) Prediction step of the peak matrix by Gaussian ARTD (gARTD) with the Gaussian process and peak detection algorithm, (2) Training step of the approximated coefficient matrix ̃ based on the multivariate-regressive formula = + (: multivariate-regression coefficient matrix, : error matrix, and : known concentration matrix of the training data set), and (3) Quantification step of the approximated concentration ̃ based on the Gauss-Newton algorithm from the predicted of the quantification data and the approximated ̃.

View Article and Find Full Text PDF