A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Combination of 180-W GreenLight XPS laser and bipolar transurethral resection of prostate for the treatment of large prostates beyond 100 ml: a novel hybrid technique. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Objectives: The aim of this study was to evaluate the safety and efficacy of the 180-W GreenLight laser (GL) XPS™ plus bipolar transurethral resection of the prostate (TURP) for the treatment of a prostate volume (PV) beyond 100 ml.

Study Design/materials And Methods: From January 2014 to December 2022, 79 patients with PV > 100 ml who underwent GL-XPS plus bipolar TURP were enrolled. The median follow-up time was 13.7 months. The International Prostate Symptom Score (IPSS), PV, uroflow study, post-void residual (PVR) volume, and prostate-specific antigen (PSA) before and after the operation were recorded. Subgroup analysis was performed to compare the outcomes between the patients with follow-up times of < 36 months and > 36 months.

Results: Statistically significant improvements in all the postoperative parameters were observed in both < 36 months and > 36 months groups. There was no blood transfusion or transurethral resection (TUR) syndrome in this series. Most of all, a second TURP was unnecessary during the follow-up. Only one (1.3%) Clavien-Dindo grade 3b complication was noted.

Conclusions: The hybrid technique of 180-W XPS™ GreenLight laser plus bipolar TURP can be safely and efficiently performed on patients with a prostate volume of > 100 ml.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11255-023-03723-wDOI Listing

Publication Analysis

Top Keywords

transurethral resection
12
180-w greenlight
8
laser bipolar
8
bipolar transurethral
8
resection prostate
8
hybrid technique
8
greenlight laser
8
prostate volume
8
bipolar turp
8
prostate
5

Similar Publications