Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Hepatic sinusoids are uniquely organized structures that help maintain a spectrum of hepatic functions. Although several in vitro liver models have been developed to replicate liver sinusoids, most of these platforms require complex, multi-step fabrication methods making it difficult to achieve truly three-dimensional (3D) channel geometries. In this study, a single-step bioprinting technique was demonstrated to simultaneously print a chip platform and develop a perfusable vascularized liver sinusoid in vitro model. The integrated system uses a co-axial-based bioprinting approach to develop a liver sinusoid-like model that consists of a sacrificial core compartment containing a perfusable pre-vascular structure and an alginate-collagen-based shell compartment containing hepatocytes. The lumen-based perfusable 3D liver sinusoid-on-a-chip (LSOC-P) demonstrated significantly better hepatocyte viability, proliferation, and liver-specific gene and protein expression compared to a 3D hepatocyte-based core/shell model with static media and the standard hepatocyte-based 2D sandwich culture system. A drug toxicity evaluation of hepatotoxins highlighted the comparatively higher sensitivity of the LSOC system with a close estimation of the therapeutic range of safe drug concentrations for humans. In conclusion, the current findings indicate that the combinatorial single-step co-axial bioprinting technique is a promising fabrication approach for the development of a perfusable LSOC platform for drug screening applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10368928PMC
http://dx.doi.org/10.1016/j.mtbio.2023.100723DOI Listing

Publication Analysis

Top Keywords

lumen-based perfusable
8
perfusable liver
8
vitro model
8
single-step bioprinting
8
bioprinting technique
8
liver
6
perfusable
5
development lumen-based
4
liver vitro
4
model
4

Similar Publications

Epidemiology, Pathophysiology, and Imaging of Atherosclerotic Intracranial Disease.

Stroke

February 2024

Department of Neurology, Vagelos College of Physicians and Surgeons, Columbia University, New York, NY (L.H.C., A.S.-A., J.G.).

Article Synopsis
  • Intracranial atherosclerotic disease (ICAD) is a leading cause of stroke, particularly affecting East Asian and non-White populations more than those of European descent.
  • ICAD not only raises the risk of stroke but also contributes to dementia and cognitive decline, with a notably high recurrence rate of over 20% for those with severe stenosis (≥70%).
  • Diagnosis primarily involves lumen-based imaging techniques, although newer methods like high-resolution vessel wall MRI may improve the identification of ICAD compared to other artery conditions.
View Article and Find Full Text PDF

Hepatic sinusoids are uniquely organized structures that help maintain a spectrum of hepatic functions. Although several in vitro liver models have been developed to replicate liver sinusoids, most of these platforms require complex, multi-step fabrication methods making it difficult to achieve truly three-dimensional (3D) channel geometries. In this study, a single-step bioprinting technique was demonstrated to simultaneously print a chip platform and develop a perfusable vascularized liver sinusoid in vitro model.

View Article and Find Full Text PDF

Vasa vasorum inside out/outside in communication: a potential role in the patency of saphenous vein coronary artery bypass grafts.

J Cell Commun Signal

December 2018

Division of Surgery and Interventional Science, Faculty of Medical Sciences, University College London Medical School, Royal Free Campus, Rowland Hill Street, London, NW3 2PF, UK.

The saphenous vein (SV) is the most commonly used conduit for revascularization in patients undergoing coronary artery bypass surgery (CABG). The patency rate of this vessel is inferior to the internal thoracic artery (ITA). In the majority of CABG procedures the ITA is removed with its outer pedicle intact whereas the (human) SV (hSV) is harvested with pedicle removed.

View Article and Find Full Text PDF

The objective of the study was to evaluate the performance of an amperometric enzyme based lactate sensor and to investigate the possibility of replacing a double lumen catheter based blood withdrawal system with a heparin coated single lumen system. The inner lumen of a double lumen catheter which was placed in a peripheral vein was perfused with heparin solution. The outer lumen was used to collect heparinized blood samples at a defined flow rate.

View Article and Find Full Text PDF