Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: Peripheral arterial stenoses (PAS) are commonly investigated with duplex ultrasound (DUS) and angiography, but these are not functional tests. Fractional flow reserve (FFR), a pressure based index, functionally assesses the ischaemic potential of coronary stenoses, but its utility in PAS is unknown. FFR in the peripheral vasculature in patients with limb ischaemia was investigated.

Methods: Patients scheduled for angioplasty and or stenting of isolated iliac and superficial femoral artery stenoses were recruited. Resting trans-lesional pressure gradient (P/P) and FFR were measured after adenosine provoked hyperaemia using an intra-arterial 0.014 inch flow and pressure sensing wire (ComboWire XT, Philips). Prior to revascularisation, exercise ABPI (eABPI) and DUS derived peak systolic velocity ratio (PSVR) of the index lesion were determined. Calf muscle oxygenation was measured using blood oxygenation level dependent cardiovascular magnetic resonance prior to and after revascularisation.

Results: Forty-one patients (32, 78%, male, mean age 65 ± 11 years) with 61 stenoses (iliac 32; femoral 29) were studied. For lesions < 80% stenosis, resting P/P was not influenced by the degree of stenosis (p = .074); however, FFR was discriminatory, decreasing as the severity of stenosis increased (p = .019). An FFR of < 0.60 was associated with critical limb threatening ischaemia (area under the curve [AUC] 0.87; 95% CI 0.75 - 0.95), in this study performing better than angiographic % stenosis (0.79; 0.63 - 0.89), eABPI (0.72; 0.57 - 0.83), and PSVR (0.65; 0.51 - 0.78). FFR correlated strongly with calf oxygenation (rho, 0.76; p < .001). A greater increase in FFR signalled resolution of symptoms and signs (ΔFFR 0.25 ± 0.15 vs. 0.13 ± 0.09; p = .009) and a post-angioplasty and stenting FFR of > 0.74 predicted successful revascularisation (combined sensitivity and specificity of 95%; AUC 0.98; 0.91 - 1.00).

Conclusion: This pilot study demonstrates that FFR can objectively measure the functional significance of PAS that compares favourably with visual and DUS based assessments. Its role as a quality control adjunct that confirms optimal vessel patency after angioplasty and or stenting also merits further investigation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10917690PMC
http://dx.doi.org/10.1016/j.ejvs.2023.07.035DOI Listing

Publication Analysis

Top Keywords

fractional flow
8
flow reserve
8
functional significance
8
peripheral arterial
8
arterial stenoses
8
angioplasty stenting
8
ffr
6
stenoses
5
intra-arterial fractional
4
reserve measurements
4

Similar Publications

Background: Previous trials have demonstrated increased 5-year risks for adverse clinical events after coronary artery implantation of poly-l-lactic acid-based bioresorbable scaffolds (BRS) compared with cobalt chromium (CoCr) everolimus-eluting stents (EES).

Objectives: The aim of this study was to evaluate the 5-year clinical outcomes of the novel sirolimus-eluting NeoVas BRS compared with CoCr EES.

Methods: A total of 560 patients with single de novo native coronary artery lesions with reference vessel diameter 2.

View Article and Find Full Text PDF

Importance: Right anomalous aortic origin of a coronary artery (R-AAOCA) is a rare congenital condition increasingly diagnosed with the growing use of cardiac imaging. Due to dynamic compression of the anomalous vessel, invasive fractional flow reserve (FFR) during a dobutamine-atropine volume challenge (FFR-dobutamine) is considered the reference standard. A reliable alternative method is needed to reduce extensive invasive testing, but it remains uncertain whether noninvasive imaging can accurately assess the hemodynamic relevance of R-AAOCA.

View Article and Find Full Text PDF

Background: The benefits of physiology-guided management in acute coronary syndrome (ACS) remain inconclusive due to limited evidence. In our FAVOR III China trial, a quantitative flow ratio (QFR)-based physiology-guided strategy versus standard angiography guidance improved the 1-year primary outcome among participants with coronary artery disease (CAD). We aimed to investigate, in a prespecified analysis, the outcomes of QFR-based physiological guidance in the FAVOR III China participants with low-risk ACS.

View Article and Find Full Text PDF

Validation of angiography-based FFR in non-culprit vessels of patients presenting with STEMI.

Clin Res Cardiol

September 2025

Department of (Interventional) Cardiology, Thoraxcenter, Erasmus University Medical Center, Room Rg-628, P.O. Box 2040, 3000 CA, Rotterdam, the Netherlands.

Background: Fractional flow reserve (FFR) for non-culprit lesions (NCLs) in patients with ST-elevation myocardial infarction (STEMI) can be influenced by temporary changes in microvascular resistance. Angiography-derived vessel fractional flow reserve (vFFR) has been tested as a less-invasive alternative.

Aims: The FAST STEMI II study aimed to assess the diagnostic performance of acute-setting vFFR vs.

View Article and Find Full Text PDF

Background: Invasive coronary physiology including fractional flow reserve (FFR), instantaneous wave-free ratio (iFR), and coronary flow reserve (CFR) are guideline-endorsed tools to guide the management of coronary artery disease (CAD). Complex factors impact and confound these assessments, and discordance between modalities complicates clinical management. iEquate is a prospective observational trial that combines multi-modality coronary physiology and optical coherence tomography (OCT) to identify the determinants of pressure-wire derived myocardial ischemia and iFR-FFR discordance.

View Article and Find Full Text PDF