98%
921
2 minutes
20
This study aims to evaluate the effect of assessing velocity time integral at different locations across ventricular outflow tracts for calculating cardiac output (CO) in neonates. Velocity time integral (VTI) and CO were measured at 3 different locations across right and left ventricular outflow tracts using transthoracic echocardiography in healthy term neonates without any major congenital heart disease. ANOVA with Bonferroni correction was used to determine the differences between the VTI and CO sampled at these three locations. Forty-one neonates met inclusion criteria with mean gestational age of 38.6 ± 1 weeks and mean birth weight of 3155 ± 463 g. The median hours after birth when echocardiography was obtained was 23 h (range 11-68 h after birth). Left CO were 121 ± 30 mL/kg/min, 155 ± 38 mL/kg/min, and 176 ± 36 mL/kg/min measured below the valve, hinges of the valve, and tip of the valve, respectively. Right CO were 197 ± 73 mL/kg/min, 270 ± 83 mL/kg/min, and 329 ± 104 mL/kg/min measured below the valve, hinges of the valve, and tip of the valve, respectively. A statistically significant difference (P < 0.001) was found in the VTI and CO measured at the 3 different locations across both left and right ventricular outflow tracts. Conclusions: There is a significant difference in measurements of VTI and CO depending on the location of Doppler gate sampling across the ventricular outflow tracts. Consistency and precision in Doppler gate location are essential for measuring VTI and calculating CO while assessing changes in hemodynamic status in critically ill infants. What is Known: • Targeted Neonatal Echocardiography is increasingly applied to measure cardiac output in critically ill neonates and serial assessments are performed to assess the trend in changes in cardiac output. • Noninvasive measurement using velocity time integral to calculate cardiac output is commonly performed. However, location of Doppler sample gate to measure ventricular outflow tract velocity time integral is not consistent. What is New: • Statistically significant changes in measured velocity time integral and cardiac output are noted based on the location of Doppler gate sampling. • To monitor the cardiac output for trending, it is important to be consistent with regards to the location of the Doppler sample gate to assess changes in cardiac output in critically ill newborns.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10593614 | PMC |
http://dx.doi.org/10.1007/s00431-023-05121-x | DOI Listing |
Sud Med Ekspert
January 2025
Russian University of Medicine, Moscow, Russia.
Unlabelled: In 2024, the 200th anniversary of the first domestic work devoted to the study of gunshot injury was celebrated.
Objective: To present little-known information from the biography of its author, Professor P.P.
Acta Neurochir (Wien)
September 2025
Department of Neurosurgery, Medical University of Gdańsk, Gdańsk, Poland.
Purpose: Moyamoya disease (MMD) is a chronic cerebrovascular disorder characterized by progressive arterial stenosis and fragile collateral formation, elevating stroke risk. Revascularization is the standard treatment, yet up to 27% of patients experience ischemic events within a year due to bypass insufficiency. While digital subtraction angiography (DSA) remains the gold standard for assessing bypass function, it is invasive and time-consuming.
View Article and Find Full Text PDFKardiologiia
September 2025
Second Affiliated Hospital of Chongqing Medical University, Department of Ultrasound Medicine.
Objective This research investigated the application of real-time, three-dimensional speckle tracking imaging (RT-3D-STI) to evaluate left atrial (LA) function in individuals suffering from hypertensive heart disease (HHD) and heart failure with preserved ejection fraction (HFpEF).Material and methods This retrospective study included 100 patients with HHD and HFpEF hospitalized from August 2023to June 2024 (HFpEF group). 100 healthy individuals undergoing physical examinations comprised the control group.
View Article and Find Full Text PDFBiochem Biophys Rep
December 2025
Henan University of Chinese Medicine, Zhengzhou, 450046, China.
Introduction: 5-Hydroxymethyl furfural (5-HMF) is a furan compound with a molecular formula of CHO. Studies have found that 5-HMF has many pharmacological effects, such as improving hemorheology, anti-inflammatory, antioxidant activity and anti-myocardial ischemia. Identifying the preventive effect of 5-HMF against ischemic stroke and its possible mechanism was the aim of this investigation.
View Article and Find Full Text PDFNMR Biomed
October 2025
Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
Understanding gastric physiology in rodents is critical for advancing preclinical neurogastroenterology research. However, existing techniques are often invasive, terminal, or limited in resolution. This study aims to develop a non-invasive, standardized MRI protocol capable of capturing whole-stomach dynamics in anesthetized rats with high spatiotemporal resolution.
View Article and Find Full Text PDF