98%
921
2 minutes
20
Background: In order to explore the surgical safety and the reliability of axillary staging of single-port endoscopic-sentinel lymph node biopsy, we combined it with indocyanine green that was excited by near-infrared fluorescence endoscopy and carbon nanoparticles as a tracer and compared this method to conventional open sentinel lymph node biopsy.
Methods: This is a retrospective and observational study, there were 20 patients in each group and the total sample size was 60: Group 1, single-port endoscopic-sentinel lymph node biopsy combined with indocyanine green and carbon nanoparticles; Group 2, single-port endoscopic-sentinel lymph node biopsy with carbon nanoparticles only; Group 3, conventional sentinel lymph node biopsy with indocyanine green and carbon nanoparticles. Sentinel lymph node detection and upper extremity function were determined to measure the safety and efficacy of the novel single-port endoscopic-sentinel lymph node biopsy (SPE-SLNB) technique to the standard conventional sentinel lymph node biopsy technique.
Results: The detection rate of sentinel lymph nodes was 100% in Group 1, 100% in Group 2, and 95% in Group 3. There were no significant differences in upper arm function and pain scores between the three groups.
Conclusion: The novel technique of combining indocyanine green and carbon nanoparticles with single-port endoscopic-sentinel lymph node biopsy achieved a similar detection rate and mean number of sentinel lymph nodes as conventional sentinel lymph node biopsy. Traditional open surgery requires two different incisions for breast surgery and SLNB. While the most important advantage of SPE-SLNB is that two procedures can be effectively performed through a single-port in the axilla Therefore, for patients who meet the indications, single-port endoscopic-sentinel lymph node biopsy is as safe and reliable as conventional sentinel lymph node biopsy but has the aesthetic advantage of only one incision.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10520094 | PMC |
http://dx.doi.org/10.1007/s00464-023-10018-9 | DOI Listing |
Eur J Case Rep Intern Med
August 2025
Division of Internal Medicine, University Hospital of Basel, Basel, Switzerland.
Unlabelled: Encephalitis is a potentially life-threatening condition with infectious or autoimmune aetiologies. Autoimmune encephalitis includes paraneoplastic variants associated with specific onconeural antibodies such as anti-Hu, frequently linked to malignancies. Herpes simplex virus type 1 (HSV-1) is the leading infectious cause in adults.
View Article and Find Full Text PDFInt J Gen Med
September 2025
Suzhou Medical College of Soochow University, Suzhou, Jiangsu, People's Republic of China.
Purpose: The fourth most common cause of cancer-related deaths in women is cervical cancer. Though treatment of early-stage cervical cancer is often effective, middle and advanced stage cervical cancer is hard to treat and prone to recurrence. We sought to explore the mechanism underlying cervical cancer progression to identify new therapeutic approaches.
View Article and Find Full Text PDFEur Heart J Case Rep
September 2025
Cardiovascular Department, Tokushima University Hospital, 7708503 Kuramoto-cho, Tokushima 2-50-1, Japan.
Background: The incidence of cancer therapy-related cardiac dysfunction is increasing with the growing number of breast cancer patients. In particular, patients with active cancer combined with severe irreversible cardiac dysfunction present significant challenges in treatment decision-making.
Case Summary: A 40-year-old woman with Stage II HER-2-positive breast cancer received anthracycline followed by HER2-targeted agents.
ERJ Open Res
September 2025
School of Public Health, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Africa.
Background: Lymph node silicosis (LNS) may be found when investigating lung and mediastinal diseases. Co-occurrence of LNS and pulmonary silicosis (PS) has been described but no studies have investigated the diagnostic accuracy of LNS for PS, the aim of this study.
Methods: This cross-sectional study included South African miners with exclusive gold-mining employment who had autopsy examinations from 1975 to 2018.
ERJ Open Res
September 2025
Division of Respiratory Medicine, Interventional Pulmonology Unit, Hospital Universitario Central de Asturias, Oviedo, Spain.
Background: The diagnostic accuracy of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for the diagnosis of lymphoma has a low overall sensitivity. The lack of tissue architecture obtained by cytological needles decreases the diagnostic accuracy for diagnosis and subtyping of and relapsed mediastinal lymphomas. This study compares the sensitivity of EBUS-TBNA and endobronchial ultrasound-guided transbronchial mediastinal cryobiopsy (EBUS-TMC) for both initial lymphoma diagnosis and recurrent cases, analyses safety, and evaluates the number of mediastinoscopies that could potentially be avoided due to this novel technique.
View Article and Find Full Text PDF