Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Electronic portal imaging devices (EPIDs) have been widely utilized for patient-specific quality assurance (PSQA) and their use for transit dosimetry applications is emerging. Yet there are no specific guidelines on the potential uses, limitations, and correct utilization of EPIDs for these purposes. The American Association of Physicists in Medicine (AAPM) Task Group 307 (TG-307) provides a comprehensive review of the physics, modeling, algorithms and clinical experience with EPID-based pre-treatment and transit dosimetry techniques. This review also includes the limitations and challenges in the clinical implementation of EPIDs, including recommendations for commissioning, calibration and validation, routine QA, tolerance levels for gamma analysis and risk-based analysis.

Methods: Characteristics of the currently available EPID systems and EPID-based PSQA techniques are reviewed. The details of the physics, modeling, and algorithms for both pre-treatment and transit dosimetry methods are discussed, including clinical experience with different EPID dosimetry systems. Commissioning, calibration, and validation, tolerance levels and recommended tests, are reviewed, and analyzed. Risk-based analysis for EPID dosimetry is also addressed.

Results: Clinical experience, commissioning methods and tolerances for EPID-based PSQA system are described for pre-treatment and transit dosimetry applications. The sensitivity, specificity, and clinical results for EPID dosimetry techniques are presented as well as examples of patient-related and machine-related error detection by these dosimetry solutions. Limitations and challenges in clinical implementation of EPIDs for dosimetric purposes are discussed and acceptance and rejection criteria are outlined. Potential causes of and evaluations of pre-treatment and transit dosimetry failures are discussed. Guidelines and recommendations developed in this report are based on the extensive published data on EPID QA along with the clinical experience of the TG-307 members.

Conclusion: TG-307 focused on the commercially available EPID-based dosimetric tools and provides guidance for medical physicists in the clinical implementation of EPID-based patient-specific pre-treatment and transit dosimetry QA solutions including intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) treatments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11230298PMC
http://dx.doi.org/10.1002/mp.16536DOI Listing

Publication Analysis

Top Keywords

transit dosimetry
24
pre-treatment transit
20
clinical experience
16
clinical implementation
12
epid dosimetry
12
dosimetry
10
aapm task
8
task group
8
dosimetry applications
8
physics modeling
8

Similar Publications

The huge volcanic eruption at Thera (Santorini), situated in the Aegean Sea, occurred within the Late Minoan IA archaeological period. However, its temporal association with Egyptian history has long been a controversial subject. Traditionally, the eruption was placed in the early 18th Dynasty, associated with Pharaoh Thutmose III as the youngest option or with Pharaoh Nebpehtire Ahmose as the oldest possibility.

View Article and Find Full Text PDF

Background: The gastrointestinal (GI) microbiota, composed of diverse microbial communities, is essential for physiological processes, including immune modulation. Strains such as Escherichia coli Nissle 1917 support gut health by reducing inflammation and resisting pathogens. Microbial therapies using such strains may restore GI balance and offer alternatives to antibiotics, whose overuse contributes to antibiotic resistance.

View Article and Find Full Text PDF

Benthic Foraminifera exhibit diverse adaptations to low oxygen (O) environments, including denitrification, a rare trait among eukaryotes. Denitrifying species store intracellular nitrate (NO ), possibly within vacuoles, and contribute significantly to the global marine nitrogen (N) cycle. Additionally, widespread phosphate (PO ) accumulation suggests a role in supporting metabolism under O-depleted conditions.

View Article and Find Full Text PDF

Intrinsic thermoluminescence and anomalous heating rate effects in undoped KSrY(BO) Phosphors: A combined T-T and GOK deconvolution study.

Appl Radiat Isot

November 2025

Jazan University, College of Science, Department of Physical Sciences, Physics Division, P.O. Box 114, 45142, Jazan, Saudi Arabia; Nanotechnology Research Unit, College of Science, Jazan University, P.O. Box. 114, Jazan, 45142, Saudi Arabia. Electronic address:

This work offers the first detailed analysis of the thermoluminescence (TL) properties of undoped KSrY(BO) phosphors prepared using a conventional solid-state method. Unlike doped systems, the TL signal in this material originates solely from intrinsic defects, making it a cost-effective and rare-earth-free option for radiation dosimetry. TL glow curves induced by β-irradiation were analyzed using Computerized Glow Curve Deconvolution (CGCD) in combination with the General Order Kinetics (GOK) model, yielding ten distinct and well-resolved peaks with activation energies ranging from 0.

View Article and Find Full Text PDF

Impact of Anthropomorphic Shape and Skin Stratification on Absorbed Power Density in mmWaves Exposure Scenarios.

Sensors (Basel)

July 2025

Istituto di Elettronica e di Ingegneria dell'Informazione e delle Telecomunicazioni (IEIIT), Consiglio Nazionale delle Ricerche (CNR), 20133 Milan, Italy.

As data exchange demands increase also in widespread wearable technologies, transitioning to higher bandwidths and mmWave frequencies (30-300 GHz) is essential. This shift raises concerns about RF exposure. At such high frequencies, the most crucial human tissue for RF power absorption is the skin, since EMF penetration is superficial.

View Article and Find Full Text PDF