Background: Few studies have reported on the quantitative evaluation of autonomic nerve modification after balloon ablation. Therefore, this study aimed to evaluate the effects of cryoballoon and hotballoon ablations on the autonomic nervous system (ANS) and their relationship with prognosis.

Methods: We included 234 patients who underwent cryoballoon ablation (n = 190) or hotballoon ablation (n = 44) for paroxysmal atrial fibrillation. Heart rate variability (HRV) analysis was performed on all patients using a 3-min electrocardiogram at baseline, 1, 3, 6, and 12 months after ablation. HRV parameters and prognoses were compared between the two balloon systems.

Results: Ln low-frequency (LF), Ln high-frequency (HF), standard deviation of the R-R intervals (SDNN), and RR intervals significantly decreased after 1 month in both groups, but the changes were more pronounced in the cryoballoon group than in the hotballoon group. In contrast, HRV indices in the hotballoon ablation group decreased gradually and reached their lowest point 3-to-6 months after the procedure, which was later than in the cryoballoon ablation group. The recurrence rate did not differ between the two groups. HRV parameters changed similarly in the cryoballoon group, regardless of recurrence. However, patients with recurrence had significantly higher SDNN and Ln LF at 12 months than those without recurrence in the hotballoon group (41.2 ± 39.3 ms vs. 18.5 ± 12.6 ms, p = 0.006, and 2.2 ± 0.7 ms vs. 1.5 ± 0.7 ms, p = 0.003, respectively).

Conclusions: The time course of HRV changes differed between cryoballoon and hotballoon ablations. Hence, the two balloon systems may have distinct effects on the ANS and its role in prognosis.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10840-023-01581-1DOI Listing

Publication Analysis

Top Keywords

cryoballoon hotballoon
12
time course
8
autonomic nervous
8
paroxysmal atrial
8
atrial fibrillation
8
hotballoon ablations
8
cryoballoon ablation
8
hotballoon ablation
8
hrv parameters
8
cryoballoon group
8

Similar Publications

Background: Catheter ablation (CA) is an effective therapeutic option for patients with symptomatic atrial fibrillation (AF). Previous studies have reported silent cerebral lesions (SCLs) detected by magnetic resonance imaging (MRI) after different CA techniques; however, the results were controversial. Therefore, we performed this network meta-analysis (NMA) to assess the incidence of SCLs after cryoballoon, hotballoon, laserballoon, and radiofrequency ablation (RFA).

View Article and Find Full Text PDF

Background: Few studies have reported on the quantitative evaluation of autonomic nerve modification after balloon ablation. Therefore, this study aimed to evaluate the effects of cryoballoon and hotballoon ablations on the autonomic nervous system (ANS) and their relationship with prognosis.

Methods: We included 234 patients who underwent cryoballoon ablation (n = 190) or hotballoon ablation (n = 44) for paroxysmal atrial fibrillation.

View Article and Find Full Text PDF

Introduction: Despite promising trials, catheter ablation is still regarded as an adjunct to antiarrhythmic drugs (AADs) in the treatment of paroxysmal atrial fibrillation (PAF). This study aimed to compare the effectiveness of various ablation therapies and AADs.

Method: Randomised controlled trials or propensity score-matched studies comparing atrial tachyarrhythmia recurrence among any combination of ablation modalities or AAD were retrieved.

View Article and Find Full Text PDF
Article Synopsis
  • Preventing phrenic nerve injury (PNI) during balloon-based ablation is crucial, as the phrenic nerve is located near the SVC-RA junction where the ablation takes place.
  • A study compared cryoballoon ablation (CBA) and hot-balloon ablation (HBA) in patients with atrial fibrillation, revealing that CBA led to a higher incidence of transient PNI (7.3% vs 1.1%) but all cases were temporary.
  • CBA created larger and more frequent lesions at the SVC-RA junction compared to HBA, suggesting that the design and positioning of the balloon systems play a significant role in the extent of damage to surrounding structures
View Article and Find Full Text PDF