A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Automatic -Axis Correction for IR-MALDESI Mass Spectrometry Imaging of Uneven Surfaces. | LitMetric

Automatic -Axis Correction for IR-MALDESI Mass Spectrometry Imaging of Uneven Surfaces.

J Am Soc Mass Spectrom

FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States.

Published: July 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Two-dimensional mass spectrometry imaging (2D MSI) experiments mainly involve samples with a flat surface and constant thickness, but some samples are challenging to section due to the texture and topography. Herein, we present an MSI method that automatically corrects for discernible height differences across surfaces during imaging experiments. A chromatic confocal sensor was incorporated into the infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) system to measure the sample surface height at the location of each analytical scan. The height profile is subsequently used for adjusting the -axis position of the sample during MSI data acquisition. We evaluated this method using a tilted mouse liver section and an unsectioned Prilosec tablet due to their exterior quasi-homogeneity and height differences of approximately ∼250 μm. MSI with automatic -axis correction showed consistent ablated spot sizes and shapes, revealing the measured ion spatial distribution across a mouse liver section and a Prilosec tablet. Conversely, irregular spots and reduced signals with large variability were observed when no -axis correction was applied.

Download full-text PDF

Source
http://dx.doi.org/10.1021/jasms.3c00151DOI Listing

Publication Analysis

Top Keywords

-axis correction
12
automatic -axis
8
mass spectrometry
8
spectrometry imaging
8
height differences
8
mouse liver
8
prilosec tablet
8
correction ir-maldesi
4
ir-maldesi mass
4
imaging uneven
4

Similar Publications