A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Quick Sequential Organ Failure Assessment Score Is a Better Predictor of Septic Shock After Percutaneous Nephrolithotomy: A Secondary Analysis of Two Multicenter Prospective Trials. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Recent retrospective literature suggests that the quick sequential organ failure assessment (qSOFA) scoring tool is a potentially superior tool over use of the systemic inflammatory response syndrome (SIRS) criteria to predict septic shock after percutaneous nephrolithotomy (PCNL) surgery. Here we examine use of qSOFA and SIRS to predict septic shock within data series collected prospectively on PCNL patients as part of a greater study of infectious complications. We performed a secondary analysis of two prospective multicenter studies including PCNL patients across nine institutions. Clinical signs informing SIRS and qSOFA scores were collected no later than postoperative day 1. The primary outcome was sensitivity and specificity of SIRS and qSOFA (high-risk score of greater-or-equal to two points) in predicting admission to the intensive care unit (ICU) for vasopressor support. A total of 218 cases at 9 institutions were analyzed. One patient required vasopressor support in the ICU. The sensitivity/specificity was 100%/72.4% (McNemar's test  < 0.001) for SIRS and was 100%/90.8% (McNemar's test  < 0.001) for qSOFA. Although positive predictive value for both qSOFA and SIRS in prediction of post-PCNL septic shock is low, prospectively collected data demonstrate use of qSOFA may offer greater specificity than SIRS criteria when predicting post-PCNL septic shock.

Download full-text PDF

Source
http://dx.doi.org/10.1089/end.2022.0677DOI Listing

Publication Analysis

Top Keywords

septic shock
12
quick sequential
8
sequential organ
8
organ failure
8
failure assessment
8
shock percutaneous
8
percutaneous nephrolithotomy
8
secondary analysis
8
predict septic
8
pcnl patients
8

Similar Publications