Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
There is insufficient information regarding the optimal guidewire for managing malignant hilar biliary obstruction (MHBO). Therefore, a newly designed 0.025-inch guidewire was compared with the conventional 0.035-inch guidewire for selective cannulation of both intrahepatic ducts (IHDs) in patients with MHBO. Patients were randomly enrolled into the curved type newly designed 0.025-inch guidewire group (0.025 group) or the curved type conventional 0.035-inch guidewire group (0.035 group). The primary outcome was the selective cannulation rate of IHD. If the assigned guidewire failed to pass the stricture within 5 min, the crossover guidewire was selected. If the crossover guidewire failed to cross the stricture within the next 5 min, it was judged as a failed selective cannulation of both IHDs. A total of 90 patients were enrolled (0.025 group, = 47; 0.035 group, = 43). There was no significant difference in baseline characteristics between the groups regarding sex, age, BMI, obstruction level, and clinical presentation. Four patients (8.5%) in the 0.025 group the cannulation of the IHD failed and the conventional 0.035-inch guidewire was substituted in a second attempt; the 0.035-inch guidewire failed to cross the stricture in all four patients. In the 0.035 group, eleven patients (25.6%) failed to achieve selective cannulation of IHD, and the 0.025-inch guidewire was substituted; the newly designed 0.025-inch guidewire crossed the stricture in ten of these (10/11, 90.9%). The selective cannulation rate of IHD was significantly higher in the 0.025 group (95.1% vs. 85.5%, = 0.043). The 0.025 group exhibited a higher success rate for selective cannulation of both IHDs in MHBO than did the 0.035 group.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10218779 | PMC |
http://dx.doi.org/10.3390/jcm12103590 | DOI Listing |