Article Abstract

To prospectively evaluate the reliability of a portable optical scanner compared to the water displacement technique for volumetric measurements of the foot and ankle and to compare the acquisition time associated with these two methods. Foot volume was measured in 29 healthy volunteers (58 feet, 24 females and 5 males) by a 3D scanner (UPOD-S 3D Laser Full-Foot Scanner®) and by water displacement volumetry. Measurements were performed on both feet, up to a height of 10 cm above the ground. The acquisition time for each method was evaluated. The Kolmogorov-Smirnov test, Lin's Concordance Correlation Coefficient, and a Student's -test were performed. Mean foot volume was 869.7 +/- 165.1 cm (3D scanner) versus 867.9 +/- 155.4 cm (water-displacement volumetry) ( < 10). The concordance of measurements was 0.93, indicative of a high correlation between the two techniques. Volumes were 47.8 cm lower when using the 3D scanner versus water volumetry. After statistically correcting this underestimation, the concordance was improved (0.98, residual bias = -0.03 +/- 35.1 cm). The mean examination time was 4.2 +/- 1.7 min (3D optical scanner) versus 11.1 +/- 2.9 min (water volumeter) ( < 10). Ankle/foot volumetric measurements performed using this portable 3D scanner are reliable and fast and can be used in clinical practice and research.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10215399PMC
http://dx.doi.org/10.3390/bioengineering10050549DOI Listing

Publication Analysis

Top Keywords

scanner versus
12
foot ankle
8
portable scanner
8
optical scanner
8
water displacement
8
volumetric measurements
8
acquisition time
8
foot volume
8
measurements performed
8
+/- min
8

Similar Publications

Purpose: This study aimed to evaluate whether low-dose CT imaging using an Sn filter can provide image quality sufficient for the differential diagnosis of cranial deformities in infants while maintaining an effective dose comparable to that of conventional radiography.

Methods: We calculated the effective dose for both head X-ray imaging and low-dose CT with an Sn filter. Phantom images acquired using a CT scanner equipped with an Sn filter were evaluated for bone suture visibility at various conditions (from 10 mAs to 50 mAs, every 10 mAs) using a 4-point visual grading scale.

View Article and Find Full Text PDF

Comparative radiation dose analysis in pediatric high-pitch cardiac CTA using photon-counting versus energy-integrating detector CT.

Pediatr Radiol

September 2025

Department of Radiology, University of Colorado School of Medicine/Department of Pediatric Radiology, Children's Hospital Colorado, 13123 East 16th Avenue, Box 125, Aurora, 80045, Colorado, USA.

Background: Previous studies have shown improved image quality in pediatric cardiac imaging using photon-counting detector CT (PCDCT). However, these studies did not evaluate image quality and radiation dose when utilizing the full spectral capabilities of PCDCT scanners. The full spectral capability of PCDCT scanners allows the generation of the entire array of mono-energetic reconstructions, virtual non-contrast (VNC) images, and iodine maps, which have potential advantages in evaluating complex congenital heart disease.

View Article and Find Full Text PDF

Effect of age and sex on cardiac magnetic resonance native T1 mapping and synthetic extracellular volume.

Int J Cardiol

August 2025

Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland; Center for Molecular Cardiology, University of Zurich, Schlieren, Switzerland.

Background: Cardiac magnetic resonance (CMR) using native T1 mapping and extracellular volume (ECV) fraction is the gold standard for noninvasive detection of diffuse myocardial fibrosis. Previous studies indicate that women tend to have higher native T1 and ECV values than men, but how these parameters evolve with cardiac aging remains unclear.

Methods And Results: Relations between age, sex, and native T1 and synthetic ECV were assessed in 306 individuals (mean age 45 ± 18 years; 47.

View Article and Find Full Text PDF

Measures of Brain Metabolism and Diffusion in Neonates of Diabetic Mothers.

AJNR Am J Neuroradiol

August 2025

From the Developing Brain Institute (S.C.N.H., N.M.H.E., J.S.N., K.K., C.L., N.A.), Division of Neonatology (N.A.), Prenatal Pediatric Institute (C.L.), Children's National Hospital, Washington, D.C. USA, Department of Radiology (S.C.N.H., N.M.H.E., C.L.), Department of Pediatrics (S.C.N.H., N.M.H.E

Background And Purpose: Maternal diabetes may affect newborns' long-term neurodevelopment and cognitive behavior. Brain biochemistry and white matter fiber tracks may reveal early changes of brain abnormality. The purpose of this study was to compare brain metabolites and fiber structures in infants of diabetic mothers (IDMs) with those of non-diabetic mothers during the early stage of neonatal neurodevelopment.

View Article and Find Full Text PDF

Accuracy of one-versus two-phase photogrammetry implant impression system: an in-vitro study.

Saudi Dent J

August 2025

Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Kanchanavanit, Hat Yai, Songkhla, Thailand.

Dental implants using digital technologies have become more popular for partial and fully edentulous patients. This in-vitro study aimed to compare the accuracy of one- and two-phase photogrammetry implant impression techniques. Six abutment-level implant analogs (screw-retained abutment diameter 4.

View Article and Find Full Text PDF