A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Sensitive determination of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol in wastewater by solid-phase extraction with pre-column derivatization and liquid chromatography-tandem mass spectrometry. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

As the dangers of cannabis abuse draw attention worldwide, it is necessary to assess the level of consumption in the community. The analysis of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH) excreted in wastewater can provide information for a defined catchment area. Due to its hydrophobic nature and absence of ionizable groups, its detection is challenging. In this study, a highly sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the quantitative determination of THC-COOH in urban wastewater. The derivatization reagent 6-methylpyridine-3-sulfonyl chloride (MPS) with analyte-specific fragmentation was proven to be the most effective for improving sensitivity. Samples were extracted by solid-phase extraction (SPE) and satisfactory recovery was achieved (>79%) by adding acetonitrile to the samples for ultrasonic-assisted extraction before filtration. The limit of detection (LOD) and limit of quantification (LOQ) was 0.03 ng L and 0.1 ng L, respectively, from a 40 mL sample. The established methodology was applied to profile the presence of THC-COOH in influent wastewater samples. It was shown that 20 out of the 252 samples contained THC-COOH and the concentrations were all below 1 ng L.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d3ay00420aDOI Listing

Publication Analysis

Top Keywords

solid-phase extraction
8
liquid chromatography-tandem
8
chromatography-tandem mass
8
mass spectrometry
8
sensitive determination
4
determination 11-nor-9-carboxy-Δ9-tetrahydrocannabinol
4
wastewater
4
11-nor-9-carboxy-Δ9-tetrahydrocannabinol wastewater
4
wastewater solid-phase
4
extraction pre-column
4

Similar Publications