Article Abstract

Purpose: To examine the biomechanical properties of rotator cuff repair with graft augmentation (RCR-G) with regard to ultimate load to failure, gap displacement, and stiffness.

Methods: A systematic review was performed by searching PubMed, the Cochrane library, and Embase using Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines to identify studies that analyzed the biomechanical properties of RCR-G. The search string implemented used the concepts "rotator cuff" and "graft," and "biomechanical" OR "cadaver." Meta-analysis was performed to provide a quantitative comparison of the 2 techniques. Primary outcome measures were ultimate load to failure (N), gap displacement (mm), and stiffness (N/mm).

Results: Our initial search yielded 1,493 articles for review. Following screening for inclusion criteria, 8 studies were included in the meta-analysis, including a total of 191 cadaveric specimens (106 RCR-G, 85 RCR). The pooled analysis from 6 studies reporting on ultimate load to failure revealed a statistically significant difference in favor of RCR-G compared with RCR (P < .001). Pooled analysis from 6 studies reporting on gap displacement failed to reveal a difference between RCR-G and RCR (P = .719). Pooled analysis from 4 studies reporting on stiffness failed to reveal a difference between RCR-G and RCR (P = .842).

Conclusions: Graft augmentation of RCR in vitro resulted in significantly increased ultimate load to failure, with no influence on gap formation or stiffness.

Clinical Relevance: The biomechanical advantage of RCR with graft augmentation demonstrated via increased ultimate load to failure in cadaveric studies may provide an explanation for the decreased RCR retear rates and improved patient reported outcomes reported in the clinical literature regarding graft augmentation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arthro.2023.04.023DOI Listing

Publication Analysis

Top Keywords

load failure
24
graft augmentation
20
ultimate load
20
gap displacement
12
rcr-g rcr
12
pooled analysis
12
analysis studies
12
studies reporting
12
rotator cuff
8
cuff repair
8

Similar Publications

Background: Choosing the appropriate implants for reconstruction in revision TKA is essential for long-term fixation. While cones and augments are routinely utilized to address tibial defects, the effect of augment location and size on the biomechanical stability of revision TKA constructs and the indications for the use of metaphyseal cones are not known.

Questions/purposes: Is the risk of cement-implant debonding of revision TKA constructs impacted by the thickness and location (medial versus bicompartmental) of tibial augments and the presence of metaphyseal cones during (1) a demanding daily activity like stair ascent and (2) torsional loads?

Methods: Under institutional review board approval, we developed patient-specific finite-element models of revision TKA from four patients (three males and one female, ages 50 to 80 years, BMI 27 to 37 kg/m2) who underwent two-stage revision and had a CT scan with no metal artifact after first-stage implant removal.

View Article and Find Full Text PDF

To investigate the axial compressive behavior of CFRP-PVC square tube-embedded aluminum concrete columns, five specimens and one control specimen without I-shaped aluminum were tested under uniaxial compression, with the number of CFRP layers and spacing as variable parameters. The failure modes, load-displacement responses, and mechanical properties such as peak load, ductility, stiffness, and energy dissipation were systematically analyzed. Results showed that the incorporation of I-shaped aluminum improved the peak load and ductility by an average of 48.

View Article and Find Full Text PDF

Background: Peripheral nerve injury commonly results in pain and long-term disability for patients. Recovery after in-continuity stretch or crush injury remains inherently unpredictable. However, surgical intervention yields the most favorable outcomes when performed shortly after injury.

View Article and Find Full Text PDF

Background: Distal triceps tendon rupture is related to high complication rates with up to 25% failures. Elbow stiffness is another severe complication, as the traditional approach considers prolonged immobilization to ensure tendon healing. Recently, a dynamic tape was designed, implementing a silicone-infused core for braid shortening and preventing repair elongation during mobilization, thus maintaining constant tissue approximation.

View Article and Find Full Text PDF

Biomechanical comparison of locking plate and pin-tension band wiring fixation for 3D-printed canine patellar fracture repair.

Front Vet Sci

August 2025

Department of Veterinary Surgery, Graduate School of Veterinary Medicine, Konkuk University, Seoul, Republic of Korea.

Introduction: The conventional pin and tension band wiring (TBW) technique remains the standard for fixation, but is frequently associated with complications such as wire breakage, loosening, and delayed healing in patellar fracture. Locking plate fixation has demonstrated superior biomechanical stability in human studies. This study aimed to compare the biomechanical performance of locking plate fixation versus TBW in canine transverse patellar fractures and to evaluate the influence of plate design on fixation strength.