A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Relevance of dedicated multiple sclerosis serum biomarkers in predicting contrast enhancement with gadolinium: Results from the REDUCE-GAD trial. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The presence of contrast enhancement (CE) on magnetic resonance imaging (MRI) is one of the principal criteria for diagnosis and disease activity of multiple sclerosis (MS). Therefore, MS patients are frequently exposed to contrast agents, which may cause deposition in the brain, restricting its use in repeat examinations. Thus, serum biomarkers may be valuable as surrogate parameters to evaluate MS activity.

Methods: REDUCE-GAD was a prospective, multicentric, biobanking study to determine whether established serum markers (neurofilament light chain [NfL], glial fibrillary acidic protein [GFAP], tau protein, ubiquitin-carboxyl-terminal-hydrolase (UCH-L1), S100B and matrix-metalloproteinase 9 [MMP9]) are predictive of CE-positive MRI lesions. Blood samples were obtained from patients undergoing MRI 5 days before or after collection.

Results: Patients (N = 102) from four different centers with confirmed MS or related disorders were included; n = 57 (55.9%) showed CE on MRI versus n = 45 (44.1%) without CE. Only higher NfL values indicated CE (odds ratio [OR] 1.05; 95% CI 1.0-1.09) and were correlated with number (ρ = 0.47; p < 0.001) and diameter of CE lesions (ρ = 0.58; p < 0.001). Nfl Z-scores improved diagnostic accuracy (OR 1.52; 95% CI 1.06-2.18). Receiver operator characteristic analysis revealed a reasonable cut-off value for NfL at 14.1 pg/mL (sensitivity 49.1%; specificity 82.2%; positive predictive value 77.8%; negative predictive value 56.0%). NfL ≥59.2 pg/mL was exclusively observed in patients with CE.

Conclusions: Evaluation of several possible serum biomarkers for CE in MS patients provided the most robust results for NfL, particularly as Z-scores. Following further evaluation, biomarkers may help stratify the application of contrast agents for brain imaging in MS patients.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ene.15865DOI Listing

Publication Analysis