Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Objective: End-stage ocular diseases usually end up with atrophic bulbi or phthisis bulbi leading to orbital volume loss which needs to be addressed. We studied the use of autologous fat for volume augmentation of the orbit because it is minimally invasive and allows early rehabilitation with the use of an artificial eye.
Design: It was a prospective, interventional study.
Methods: A total of 14 eyes of 14 patients with atrophic bulbi with shrinkage or phthisis bulbi with no perception of light (PL) and aged older than 18 years were included for the study purpose. Painful or inflamed eyes or suspected intraocular tumors were excluded. An autologous fat graft was obtained from the lower abdomen or buttocks and injected into the retrobulbar space using a 20-gauge cannula after adequate peribulbar anesthesia. Outcomes measures were patient satisfaction, change in Hertel's exophthalmometry, vertical and horizontal palpebral aperture, and socket volume.
Results: Hertel exophthalmometry showed a significant improvement both with and without an artificial eye from 14.92 ± 2.3 mm to 16.71 ± 1.94 mm (p-value 0.003 without an artificial eye). The vertical palpebral aperture also showed a significant improvement from 5 ± 1.70 mm to 6.71 ± 1.58 mm (p-value < 0.001). There was a significant reduction in the socket volume from 1.22 ml to 0.39 ml (p-value < 0.001). No local or donor site complications were seen.
Conclusions: Autologous fat transfer is a minimally invasive, safe, and effective procedure for orbital volume augmentation in small, nonseeing eyes. The short-term outcome of our study was good in most patients and can be considered for such patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bjps.2023.02.024 | DOI Listing |