A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Numerical analysis of hafnium oxide and phase change material-based multi-layered infrared and visible frequency sensor for biomolecules sensing application. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We report on the results of a numerical investigation into a phase transition material and hafnium (IV) oxide-based refractive index sensor with a wide spectral range, including both the visible and infrared regions of the electromagnetic spectrum. The sensor relies on hafnium (IV) oxide and a phase transition material (HfO). Three layered versions of the proposed structure are studied; each configuration is built from alternating layers of HfO, silica, GeSbTe(GST), and silver. The three different arrangements have all been studied. The reflectance response of such multilayer structures is discussed in this manuscript for refractive indices ranging from 1 to 2.4. In addition, we have investigated how the varying heights of the materials affect the overall performance of the structure. Finally, we have supplied several formulae for resonating traces that may be used to calculate the sensing behaviour across a specific wavelength range and refractive index values. The corresponding equations are shown below. We have computed numerous equation traces throughout this inquiry to calculate the wavelength and refractive index values. Computational methods may be used to analyze the proposed structure, which might aid in creating biosensors for detecting a wide variety of biomolecules and biomarkers, such as saliva-cortisol, urine, glucose, cancerous and cancerous, and hemoglobin.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10175553PMC
http://dx.doi.org/10.1038/s41598-023-34817-1DOI Listing

Publication Analysis

Top Keywords

hafnium oxide
8
oxide phase
8
phase transition
8
transition material
8
proposed structure
8
refractive values
8
numerical analysis
4
analysis hafnium
4
phase change
4
change material-based
4

Similar Publications