A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Adjustable, Dynamic Subcortical Stimulation Technique for Brain Tumor Resection: A Case-Series. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Objectives: Subcortical stimulation (SCS) is the gold standard neuromonitoring technique for intraoperative identification of descending white matter tracts. Dynamic SCS confers several advantages over more commonly used static devices; however, current commercially available devices for dynamic SCS have not been widely adopted.

Methods: We fashioned a dynamic SCS device using a stainless-steel suction and commonly available materials and assessed its efficacy in a series of 14 patients with brain tumors. The device was used to provide continuous SCS during tumor resection. Preoperative and postoperative motor function were characterized, and preoperative and postoperative imaging were analyzed to determine extent of tumor resection and proximity to motor-eloquent structures. Inferential statistics were used to correlate study parameters.

Results: Fourteen patients (12 male and 2 female, median age 52.5 years) were analyzed. The lowest intraoperative SCS intensities were 10 to 15 mA (3 surgeries), 5 to 10 mA (4 surgeries), and <5 mA (2 surgeries). SCS with this device did not elicit motor evoked potentials in 5 surgeries because of distance from the corticospinal tract (CST) and served as negative controls. Three patients (21.4%) experienced new postoperative motor deficits immediately after surgery that resolved by discharge. We observed no instances of mechanical CST injury resulting in permanent postoperative motor deficits using this technique and no correlation between lower SCS intensity and the presence of new motor impairments after surgery. No patient experienced an intraoperative seizure.

Conclusion: The novel dynamic SCS device is easily adoptable and allows accurate intraoperative identification of the CST, facilitating safe resection of tumors near motor-eloquent structures.

Download full-text PDF

Source
http://dx.doi.org/10.1227/ons.0000000000000724DOI Listing

Publication Analysis

Top Keywords

tumor resection
12
dynamic scs
12
subcortical stimulation
8
preoperative postoperative
8
scs
6
adjustable dynamic
4
dynamic subcortical
4
stimulation technique
4
technique brain
4
brain tumor
4

Similar Publications