98%
921
2 minutes
20
Aims: The pressure increase per time unit (dP/dt) in aortic stenosis (AS) jet velocity is assumed to have inter-individual variability in the progressive AS stage. We sought to examine the association of aortic valve (AoV) Doppler-derived dP/dt in patients with mild to moderate AS with risk of progression to severe disease.
Methods And Results: A total of 481 patients diagnosed with mild or moderate AS [peak aortic jet velocity (Vmax) between 2 and 4 m/s] according to echocardiographic criteria were included. AoV Doppler-derived dP/dt was determined by measuring the time needed for the pressure to increase at a velocity of the AoV jet from 1 m/s to 2 m/s. During a median follow-up period of 2.7 years, 12 of 404 (3%) patients progressed from mild to severe AS and 31 of 77 (40%) patients progressed from moderate to severe AS. AoV Doppler-derived dP/dt had a good ability to predict risk of progression to severe AS (area under the curve = 0.868) and the cut-off value was 600 mmHg/s. In multivariable logistic regression, initial AoV calcium score (adjusted odds ratio [aOR], 1.79; 95% confidence interval [CI], 1.18-2.73; P = 0.006) and AoV Doppler-derived dP/dt (aOR, 1.52/100 mmHg/s higher dP/dt; 95% CI, 1.10-2.05; P = 0.012) were associated with progression to severe AS.
Conclusion: AoV Doppler-derived dP/dt above 600 mmHg/s was associated with risk of AS progression to the severe stage in patients with mild to moderate AS. This may be useful in individualized surveillance strategies for AS progression.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/ehjci/jead099 | DOI Listing |
Eur Heart J Cardiovasc Imaging
August 2023
Division of Cardiology, Department of Internal Medicine, Kangwon National University Hospital, Kangwon National University School of Medicine, Chuncheon-si, Gangwon-do, 24289, Republic of Korea.
Aims: The pressure increase per time unit (dP/dt) in aortic stenosis (AS) jet velocity is assumed to have inter-individual variability in the progressive AS stage. We sought to examine the association of aortic valve (AoV) Doppler-derived dP/dt in patients with mild to moderate AS with risk of progression to severe disease.
Methods And Results: A total of 481 patients diagnosed with mild or moderate AS [peak aortic jet velocity (Vmax) between 2 and 4 m/s] according to echocardiographic criteria were included.
Equine Vet J
November 2018
Department of Veterinary Medical Sciences, University of Bologna, Ozzano Emilia, Bologna, Italy.
Background: In dogs, due to better alignment with the aortic outflow, the subcostal (SC) transducer site provides greater Doppler-derived velocities than those obtained from the left parasternal view. The feasibility of this imaging approach has never been described in equine echocardiography.
Objectives: The objective of this study was to evaluate the feasibility of the SC view in newborn foals and compare aortic two-dimensional and Doppler-derived velocity measurements with those of standard parasternal long-axis (LAX) views.
Ultrasound Obstet Gynecol
November 2017
Department of Cardiology, Boston Children's Hospital, Boston, MA, USA.
Objectives: Although the postnatal physiology of D-loop transposition of the great arteries with intact ventricular septum (D-TGA/IVS) is well established, little is known about fetal D-TGA/IVS. In the normal fetus, the pulmonary valve (PV) is larger than the aortic valve (AoV), there is exclusive right-to-left flow at the foramen ovale (FO) and ductus arteriosus (DA), and the left ventricle (LV) ejects 40% of combined ventricular output (CVO) through the aorta, primarily to the brain. In D-TGA/IVS, the LV ejects oxygen-rich blood to the pulmonary artery, theoretically leading to pulmonary vasodilation, increased branch pulmonary artery flow and reduced DA flow.
View Article and Find Full Text PDF