A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Evaluation of the FLEXotendon glove-III through a human subject case study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Cervical spinal cord injury (SCI) can significantly impair an individual's hand functionality due to the disruption of nerve signals from the brain to the upper extremity. Robotic assistive hand exoskeletons have been proposed as a potential technology to facilitate improved patient rehabilitation outcomes, but few exoskeleton studies utilize standardized hand function tests and questionnaires to produce quantitative data regarding exoskeleton performance. This work presents the human subject case study evaluation of the FLEXotendon Glove-III, a 5 degree-of-freedom voice-controlled, tendon-driven soft robotic assistive hand exoskeleton for individuals with SCI. The exoskeleton system was evaluated in a case study with two individuals with SCI through two standardized hand function tests namely, the Jebsen-Taylor Hand Function Test and the Toronto Rehabilitation Institute Hand Function Test and three questionnaires (Capabilities of Upper Extremities Questionnaire, Orthotics Prosthetics Users Survey, Quebec User Evaluation of Satisfaction with Assistive Technology). Minor design changes were made to the exoskeleton: integrated fingertip force sensors to sense excessive grasp force, a quick connect system to expedite the exoskeleton glove swapping process between users, compact tendon tension sensors to measure tendon force for admittance control, and a redesigned smartphone app to encompass all aspects of exoskeleton use.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10130284PMC
http://dx.doi.org/10.1007/s13534-023-00262-2DOI Listing

Publication Analysis

Top Keywords

hand function
16
case study
12
evaluation flexotendon
8
flexotendon glove-iii
8
human subject
8
subject case
8
robotic assistive
8
assistive hand
8
standardized hand
8
function tests
8

Similar Publications