A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Optimization and Validation of Dispersive Liquid-Liquid Microextraction for Simultaneous Determination of Aflatoxins B1, B2, G1, and G2 in Senna Leaves and Pods Using HPLC-FLD with Pre-Column Derivatization. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Dispersive liquid-liquid microextraction (DLLME) was optimized for the simultaneous extraction of aflatoxins (AFB1, AFB2, AFG1, and AFG2) from powdered senna leaves and pods. Detection was performed using high-performance liquid chromatography with fluorescence detection (HPLC-FLD) and pre-column derivatization. The parameters affecting the DLLME extraction efficiency were evaluated. Chloroform (200 µL) was used as an extraction solvent, 500 µL of distilled water was used as a dispersive solvent, and the extraction was performed at pH 5.6 with no salt added. The optimized method was validated using leaves and pods according to the European Commission guidelines. The linear range for all aflatoxins was 2-50 µg/kg, with values for regression coefficients of determination exceeding 0.995. The recoveries of spiked senna leaves and pods were in the ranges of 91.77-108.71% and 83.50-102.73%, respectively. The RSD values for intra-day and inter-day precisions were in the ranges of 2.30-7.93% and 3.13-10.59%, respectively. The limits of detection and quantification varied in the ranges of 0.70-1.27 µg/kg and 2.13-3.84 µg/kg, respectively. The validated method was successfully applied for the quantification of aflatoxins in 60 real samples of dried senna leaves and pods.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10142810PMC
http://dx.doi.org/10.3390/toxins15040277DOI Listing

Publication Analysis

Top Keywords

leaves pods
20
senna leaves
16
dispersive liquid-liquid
8
liquid-liquid microextraction
8
hplc-fld pre-column
8
pre-column derivatization
8
leaves
5
pods
5
optimization validation
4
validation dispersive
4

Similar Publications