Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Polycyclic aromatic hydrocarbons (PAHs) were included as priority substances for human biomonitoring (HBM) in the European Human Biomonitoring Initiative (HBM4EU), which intended to harmonise and advance HBM across Europe. For this project, a specific Quality Assurance and Quality Control (QA/QC) programme applying Inter-laboratory Comparison Investigations (ICIs) and External Quality Assurance Schemes (EQUASs) was developed to ensure the comparability and accuracy of participating analytical laboratories. This paper presents the results of four ICI/EQUAS rounds for the determination of 13 PAH metabolites in urine, i.e. 1-naphthol, 2-naphthol, 1,2-dihydroxynaphthalene, 2-, 3- and 9-hydroxyfluorene, 1-, 2-, 3-, 4- and 9-hydroxyphenanthrene, 1-hydroxypyrene and 3-hydroxybenzo(a)pyrene. However, 4 PAH metabolites could not be evaluated as the analytical capacity of participating laboratories was too low. Across all rounds and biomarkers, 86% of the participants achieved satisfactory results, although low limits of quantification were required to quantify the urinary metabolites at exposure levels of the general population. Using high-performance liquid or gas chromatography coupled with mass spectrometry (HPLC-MS; GC-MS) and isotope dilution for calibration as well as performing an enzymatic deconjugation step proved to be favourable for the accurate determination of PAHs in urine. Finally, the HBM4EU QA/QC programme identified an international network of laboratories providing comparable results in the analysis of urinary PAH biomarkers, although covering all parameters initially selected was still too challenging.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijheh.2023.114169 | DOI Listing |