Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: In this study, we investigated whether deep learning-based prediction of osseointegration of dental implants using plain radiography is possible.
Methods: Panoramic and periapical radiographs of 580 patients (1,206 dental implants) were used to train and test a deep learning model. Group 1 (338 patients, 591 dental implants) included implants that were radiographed immediately after implant placement, that is, when osseointegration had not yet occurred. Group 2 (242 patients, 615 dental implants) included implants radiographed after confirming successful osseointegration. A dataset was extracted using random sampling and was composed of training, validation, and test sets. For osseointegration prediction, we employed seven different deep learning models. Each deep-learning model was built by performing the experiment 10 times. For each experiment, the dataset was randomly separated in a 60:20:20 ratio. For model evaluation, the specificity, sensitivity, accuracy, and AUROC (Area under the receiver operating characteristic curve) of the models was calculated.
Results: The mean specificity, sensitivity, and accuracy of the deep learning models were 0.780-0.857, 0.811-0.833, and 0.799-0.836, respectively. Furthermore, the mean AUROC values ranged from to 0.890-0.922. The best model yields an accuracy of 0.896, and the worst model yields an accuracy of 0.702.
Conclusion: This study found that osseointegration of dental implants can be predicted to some extent through deep learning using plain radiography. This is expected to complement the evaluation methods of dental implant osseointegration that are currently widely used.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10082489 | PMC |
http://dx.doi.org/10.1186/s12903-023-02921-3 | DOI Listing |