A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Rule of four: an anatomic and value-based approach to stent-graft inventory for blunt thoracic aortic injury. | LitMetric

Rule of four: an anatomic and value-based approach to stent-graft inventory for blunt thoracic aortic injury.

Eur J Trauma Emerg Surg

Department of Surgery and Perioperative Care, Dell Medical School, University of Texas at Austin, 1500 Red River Street, Annex, Austin, TX, 78701, USA.

Published: October 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: As blunt thoracic aortic injury (BTAI) treatment has shifted from open to thoracic endovascular aortic repair (TEVAR), logistical challenges exist in creating and maintaining inventories of appropriately sized stent-grafts, including storage demands, shelf-life management and cost. We hypothesized that most injured aortas can be successfully repaired with a narrow range of stent-graft sizes and present a value-based anatomic approach to optimizing inventory.

Methods: CT-scans of all patients with BTAI admitted to our Level I trauma center from Apr 2010-Dec 2018 were reviewed. Patients with anatomy incompatible with TEVAR were excluded. For each patient, after aortic sizing a set of two stent-grafts most likely to be utilized was selected from a list of twenty commercially available GORE conformable TAG endografts based on manufacturer instructions. Stent-graft sizes were then ranked based on the number of cases they would be suitable for. MATLAB was utilized to determine the combinations of stent-grafts which would cover the most patients.

Results: Twenty-eight patients with BTAI were identified and three were excluded based on iliac diameter. Most patients were male (68%), mean age 42.3 ± 20.2 years, mean ISS 37.0 ± 9.8. Overall mortality was 25%. Of the 20 available stent-graft options, a combination of four stent-grafts would successfully treat 100% of the patients in this series.

Conclusions: Based on actual CT-scan aortic measurements, we demonstrated that an inventory of four sent-graft sizes was sufficient to treat 100% of patients with BTAI. These data can be utilized as a value-based anatomic approach to aortic stent-graft institutional inventory creation and maintenance.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00068-023-02267-zDOI Listing

Publication Analysis

Top Keywords

patients btai
12
blunt thoracic
8
thoracic aortic
8
aortic injury
8
stent-graft sizes
8
value-based anatomic
8
anatomic approach
8
treat 100%
8
100% patients
8
aortic
6

Similar Publications