Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Purpose: As blunt thoracic aortic injury (BTAI) treatment has shifted from open to thoracic endovascular aortic repair (TEVAR), logistical challenges exist in creating and maintaining inventories of appropriately sized stent-grafts, including storage demands, shelf-life management and cost. We hypothesized that most injured aortas can be successfully repaired with a narrow range of stent-graft sizes and present a value-based anatomic approach to optimizing inventory.
Methods: CT-scans of all patients with BTAI admitted to our Level I trauma center from Apr 2010-Dec 2018 were reviewed. Patients with anatomy incompatible with TEVAR were excluded. For each patient, after aortic sizing a set of two stent-grafts most likely to be utilized was selected from a list of twenty commercially available GORE conformable TAG endografts based on manufacturer instructions. Stent-graft sizes were then ranked based on the number of cases they would be suitable for. MATLAB was utilized to determine the combinations of stent-grafts which would cover the most patients.
Results: Twenty-eight patients with BTAI were identified and three were excluded based on iliac diameter. Most patients were male (68%), mean age 42.3 ± 20.2 years, mean ISS 37.0 ± 9.8. Overall mortality was 25%. Of the 20 available stent-graft options, a combination of four stent-grafts would successfully treat 100% of the patients in this series.
Conclusions: Based on actual CT-scan aortic measurements, we demonstrated that an inventory of four sent-graft sizes was sufficient to treat 100% of patients with BTAI. These data can be utilized as a value-based anatomic approach to aortic stent-graft institutional inventory creation and maintenance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00068-023-02267-z | DOI Listing |