Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In this article, we consider the mean residual life regression model in the presence of covariate measurement errors. In the whole cohort, the surrogate variable of the error-prone covariate is available for each subject, while the instrumental variable (IV), which is related to the underlying true covariates, is measured only for some subjects, the calibration sample. Without specifying distributions of measurement errors but assuming that the IV is missing at random, we develop two estimation methods, the IV calibration and cohort estimators, for the regression parameters by solving estimation equations (EEs) based on the calibration sample and cohort sample, respectively. To improve estimation efficiency, a synthetic estimator is derived by applying the generalized method of moment for all EEs. The large sample properties of the proposed estimators are established and their finite sample performance are evaluated via simulation studies. Simulation results show that the cohort and synthetic estimators outperform the IV calibration estimator and the relative efficiency of the cohort and synthetic estimators mainly depends on the missing rate of IV. In the case of low missing rate, the synthetic estimator is more efficient than the cohort estimator, while the result can be reversed when the missing rate is high. We illustrate the proposed method by application to data from the patients with stage 5 chronic kidney disease in Taiwan.

Download full-text PDF

Source
http://dx.doi.org/10.1002/sim.9736DOI Listing

Publication Analysis

Top Keywords

measurement errors
12
missing rate
12
residual life
8
presence covariate
8
covariate measurement
8
calibration sample
8
synthetic estimator
8
cohort synthetic
8
synthetic estimators
8
cohort
6

Similar Publications

Estimation of Brachial-Ankle Pulse Wave Velocity With Hierarchical Regression Model From Wrist Photoplethysmography and Electrocardiographic Signals: Method Design.

JMIR Biomed Eng

August 2025

Cardiovascular Center and Divisions of Cardiology and Hospital Medicine, Department of Internal Medicine, National Taiwan University Hospital, No.7, Chung Shan S Rd, Taipei, 100225, Taiwan, 886 2-2312-3456.

Background: Photoplethysmography (PPG) signals captured by wearable devices can provide vascular age information and support pervasive and long-term monitoring of personal health condition.

Objective: In this study, we aimed to estimate brachial-ankle pulse wave velocity (baPWV) from wrist PPG and electrocardiography (ECG) from smartwatch.

Methods: A total of 914 wrist PPG and ECG sequences and 278 baPWV measurements were collected via the smartwatch from 80 men and 82 women with average age of 63.

View Article and Find Full Text PDF

Introduction: Intrinsic foot muscles and the plantar fascia are crucial for foot health, which diminishes with age and conditions such as chronic plantar fasciitis (PF). Ultrasound (US) is an accessible and cost-effective method for evaluating these structures. This study aims to assess the repeatability, reliability, and validity of plantar fascia thickness and flexor digitorum brevis (FDB) muscle measurements using US compared with MRI in individuals with and without PF.

View Article and Find Full Text PDF

Purpose: This study sought to determine the intrasession repeatability of the diffusion-weighted (DW) arterial spin labeling (ASL) sequence at different postlabel delays (PLDs).

Methods: We first performed numerical simulations to study the accuracy of the two-compartment water exchange rate (Kw) fitting model with added Gaussian noise for DW PLDs at 1500, 1800, and 2100 ms. Ten young, healthy participants then underwent a structural T scan and two intrasession in vivo DW ASL scans at each PLD on a 3T MRI.

View Article and Find Full Text PDF

Rationale: Chrysotoxine, a bibenzyl derivative from the stems of Dendrobium medicinal herbs, has recently emerged as a promising therapeutic candidate for cervical cancer. This study aimed to characterize chrysotoxine metabolites across multiple hepatocyte species and in rat urine.

Methods: Metabolites were identified and characterized using liquid chromatography coupled with benchtop Orbitrap high-resolution mass spectrometry (LC-Orbitrap-MS/MS) combined with Compound Discoverer software.

View Article and Find Full Text PDF

Quantum simulations of many-body systems are among the most promising applications of quantum computers. In particular, models based on strongly correlated fermions are central to our understanding of quantum chemistry and materials problems, and can lead to exotic, topological phases of matter. However, owing to the non-local nature of fermions, such models are challenging to simulate with qubit devices.

View Article and Find Full Text PDF