Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Respiratory motion presents a challenge in radiotherapy of thoracic and upper abdominal tumors. Techniques to account for respiratory motion include tracking. Using magnetic resonance imaging (MRI) guided radiotherapy systems, tumors can be tracked continuously. Using conventional linear accelerators, tracking of lung tumors is possible by determining tumor motion on kilo voltage (kV) imaging. But tracking of abdominal tumors with kV imaging is hampered by limited contrast. Therefore, surrogates for the tumor are used. One of the possible surrogates is the diaphragm. However, there is no universal method for establishing the error when using a surrogate and there are particular challenges in establishing such errors during free breathing (FB). Prolonged breath-holding might address these challenges.

Purpose: The aim of this study was to quantify the error when using the right hemidiaphragm top (RHT) as surrogate for abdominal organ motion during prolonged breath-holds (PBH) for possible application in radiation treatments.

Methods: Fifteen healthy volunteers were trained to perform PBHs in two subsequent MRI sessions (PBH-MRI1 and PBH-MRI2). From each MRI acquisition, we selected seven images (dynamics) to determine organ displacement during PBH by using deformable image registration (DIR). On the first dynamic, the RHT, right and left hemidiaphragm, liver, spleen and right and left kidney were segmented. We used the deformation vector fields (DVF), generated by DIR, to determine the displacement of each organ between two dynamics in inferior-superior (IS), anterior-posterior (AP), left-right (LR) direction and we calculated the 3D vector magnitude (|d|). The displacements of the RHT, both hemidiaphragms and the abdominal organs were compared using a linear fit to determine the correlation (R of the fit) and the displacement ratio (DR, slope of the fit) between displacements of the RHT and each organ. We quantified the median difference between the DRs of PBH-MRI1 and PBH-MRI2 for each organ. Additionally, we estimated organ displacement in the second PBH by applying the DR from the first PBH to the displacement of the RHT measured during the second PBH. We compared the estimated organ displacement to the measured organ displacement during the second PBH. The difference between the two values was defined as the estimation error of using the RHT as a surrogate and assuming a constant DR over MRI sessions.

Results: The linear relationships were confirmed by the high R values of the linear fit between the displacements of the RHT and the abdominal organs (R > 0.96) in the IS and AP direction and |d|, and high to moderate correlations in the LR direction (0.93 > R > 0.64). The median DR difference between PBH-MRI1 and PBH-MRI2 varied between 0.13 and 0.31 for all organs. The median estimation error of the RHT as a surrogate varied between 0.4 and 0.8 mm/min for all organs.

Conclusion: The RHT could serve as an accurate surrogate for abdominal organ motion during radiation treatments, for example, in tracking, provided the error of the RHT as motion surrogate is taken into account in the margins.

Trial Registration: The study was registered in the Netherlands Trial Register (NL7603).

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.16403DOI Listing

Publication Analysis

Top Keywords

organ displacement
16
abdominal organ
12
organ motion
12
rht surrogate
12
pbh-mri1 pbh-mri2
12
displacements rht
12
second pbh
12
error rht
12
organ
10
rht
10

Similar Publications

Background: The greatest advantage of robotic surgery is that it enables precise surgery through a magnified three-dimensional (3D) image effect, multi-degree-of-freedom forceps, and a stable surgical field. However, it has disadvantages such as lack of tactile sensation and the existence of blind spots and the possibility of organ damage is higher in comparison to open or laparoscopic surgery. To solve these two major problems, we developed BirdView™, a wide view camera system.

View Article and Find Full Text PDF

A PEDIATRIC HEALTH PROBLEM INCREASING WITH MIGRATION: PERTUSSIS RELOADING.

Int J Infect Dis

September 2025

Chief of Department of Pediatrics, University of Health Sciences, Mersin City Education and Research Hospital, Turkey. Electronic address:

Objective: Bordetella pertussis is a highly contagious respiratory infection affecting infants, particularly those in vulnerable populations. This study investigates the increase in pertussis cases following refugee influxes and natural disasters.

Methods: This retrospective study analyzed 28 infants hospitalized in our hospital's pediatric ward due to whooping cough between December 27, 2023, and April 30, 2024.

View Article and Find Full Text PDF

An Engineered Supramolecular Fluorescent Chemosensor for Multiscale Visualization of Glutamate Dynamics in Living Systems.

J Am Chem Soc

September 2025

Shanghai Key Laboratory of Green Chemistry and Chemical Processes, School of Chemistry and Molecular Engineering, East China Normal University, Shanghai 200241, P. R. China.

Glutamate (Glu) plays a critical role in the brain, and the ability to directly measure glutamate activity is essential for understanding its physiological functions and pathological processes. Herein, we engineered a family of Glu sensors () based on host-guest interactions through the indicator displacement method (IDA) strategy. The optimized supramolecular chemosensor exhibited specificity, sensitivity, signal-to-noise ratio, rapid kinetics (∼145 ms), and photostability, enabling it to be suitable for monitoring Glu dynamics in neuronal organelles, brain tissues, and zebrafish.

View Article and Find Full Text PDF

Background: Tracking irradiation to moving targets in spot-scanning particle therapy, which corrects the spot position and energy in real-time, may decrease treatment time and increase accuracy. However, because of the temporal performance of the system, clinical translation remains challenging. Processing time, including image acquisition, volumetric image synthesis, correction assessment, and system response, is required to control the actual treatment system.

View Article and Find Full Text PDF

Label-free structural and mechanical characterization of rat uterosacral ligaments.

Acta Biomater

August 2025

STRETCH Lab, Virginia Tech, 330A Kelly Hall, 325 Stanger Street, Blacksburg, 24061, VA, USA. Electronic address:

This study presents quantitative applications of label-free imaging methods to characterize the structure of the uterosacral ligaments (USLs) before, during, and after loading. Rat USLs (n=14) were excised with their spinal and cervical attachments, clamped at these attachment sites, and pulled uniaxially in a custom-built tensile testing machine along their main in vivo loading direction. During uniaxial testing, optical coherence tomography (OCT) images were recorded, revealing the re-arrangement and failure of the structural components of the USLs.

View Article and Find Full Text PDF