A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Criterion-related validity and reliability of the 2-km walk test and the 20-m shuttle run test in adults: The role of sex, age and physical activity level. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: To analyze the criterion-related validity and the reliability of fitness field tests for evaluating cardiorespiratory fitness in adults, by sex, age, and physical activity level.

Design: Cross-sectional.

Methods: During 3 weeks, sociodemographic, anthropometric measurements, a treadmill maximal test, the 2-km walk test, and the 20-m SRT were performed in 410 adults aged 18-64 years. Measured and estimated VO (by Oja's and Leger's equations) were analyzed.

Results: Measured VO was associated with estimated VO by the 2-km walk test and 20-m SRT (r = 0.784 and r = 0.875, respectively; both p < 0.01). Bland-Altman analysis showed a mean difference of -0.30 ml* kg * min (p < 0.001, d = -0.141) in the 2-km walk test, and 0.86 ml* kg * min (p = 0.051) in the 20-m SRT. Significant mean differences between test and retest were found in the time to complete the 2-km walk test (-1.48 ± 0.51 s, p = 0.004, d = -0.014) and in the final stage reached in the 20-m SRT (0.04 ± 0.01, p = 0.002, d = 0.015). Non-significant differences were found between test and retest in the estimated VO by Oja's (-0.29 ± 0.20 ml* kg * min, p > 0.05) and Leger's eqs. (0.03 ± 0.04 ml* kg * min, p > 0.05). Moreover, both test results and estimated VO equations showed a high test-retest reliability.

Conclusions: Both tests were valid and reliable for evaluating cardiorespiratory fitness in adults aged 18-64 years, regardless of sex, age, and physical activity level.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jsams.2023.03.005DOI Listing

Publication Analysis

Top Keywords

2-km walk
12
walk test
12
test 20-m
12
sex age
12
age physical
12
physical activity
12
criterion-related validity
8
validity reliability
8
activity level
8
evaluating cardiorespiratory
8

Similar Publications