A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Clinical and anatomic correlates of objectively measured zonular dehiscence in 427 postmortem pseudophakic eyes. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: This study aims to objectively measure the degree of zonular dehiscence in postmortem eyes and to assess for clinical and anatomic correlates.

Design: Cross-sectional study.

Materials: Four hundred and twenty-seven postmortem pseudophakic human eyes.

Methods: Eyes were obtained from the Lions Gift of Sight Eye Bank. Microscope photographs were taken of the eyes in Miyake-Apple view, and region-of-interest analysis was performed using ImageJ to measure the area, circumference, and diameter of the capsular bag, the ciliary ring, and the capsulorhexis. Clinical and anatomic parameters were assessed using simple linear regression analysis and one-way analysis of variance with post hoc Bonferroni testing. Zonular dehiscence was measured via 2 surrogates: capsule area over ciliary ring area ratio (CCR) and capsule-ciliary ring decentration (CCD). Low CCR and high CCD indicate more zonular dehiscence.

Results: CCR was significantly inversely correlated with smaller capsulorhexi (p = 0.012), lower intraocular lens power (p < 0.00001), younger age at death (p = 0.00002), and a longer cataract-to-death time (p = 0.00786). CCR also was significantly lower in glaucomatous cases (p = 0.0291). CCD was significantly correlated with longer cataract-to-death time (p = 0.000864), larger ciliary ring area (p = 0.001), more posterior capsule opacification (p = 0.0234), and higher Soemmering's ring opacity (p = 0.0003). There was also significantly more decentration in male eyes than in female eyes (p = 0.00852).

Conclusions: CCR and CCD are novel measures of zonular dehiscence in postmortem eyes, with many interesting correlates. An enlarged ciliary ring area is possibly associated with zonular dehiscence in pseudophakic eyes and may be a quantifiable surrogate in vivo.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcjo.2023.03.001DOI Listing

Publication Analysis

Top Keywords

zonular dehiscence
20
ciliary ring
16
clinical anatomic
12
ring area
12
postmortem pseudophakic
8
eyes
8
pseudophakic eyes
8
dehiscence postmortem
8
postmortem eyes
8
longer cataract-to-death
8

Similar Publications