A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A versatile and fast-sampling rate wearable analog data logger. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We propose a wearable, versatile, and open-source data logger that harvests the capacities of a low-cost microcontroller and enables fast-sampling recording of Analog signals into a microSD card. We describe here the circuit design and an exhaustive list of instructions to build a small, lightweight, and fast sampling rate data logger (up to 5 kHz for simultaneous recording of 3 channels and up to 40 kHz when using a single channel). We provide data analysis instructions, including publicly available scripts to facilitate its replication and customization. As a straightforward proof-of-concept, we tested our device embedded with a three-axial Analog accelerometer and were able to record triple axis acceleration of body movements in high resolution. A Fourier transform followed by a principal component analysis discriminated accurately between body motions of two participants and two types of movement recorded (walking VS running). Our wearable and fast-sampling rate data logger overcomes limits that we identified in previous studies, by being low-cost, capable of fast sampling rate, and easily replicated. Moreover, it can be customized to fit with a wide variety of applications in biomedical research by substituting the three-axial Analog accelerometer with virtually any type of Analog sensors or devices that output Analog signals. •We present a method to build and use a low-cost, fast-sampling rate and wearable Analog data logger, where having an engineering background is not required.•The data logger we present can collect Analog signals from 3 channels simultaneously at 5kHz and up to 40 kHz when using a single channel.•We demonstrate that our data logger can record data from a triple axis Analog accelerometer at 5 kHz, however, signals from virtually any Analog sensor or device that outputs Analog signals can be collected.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10026020PMC
http://dx.doi.org/10.1016/j.mex.2023.102098DOI Listing

Publication Analysis

Top Keywords

data logger
28
analog signals
16
fast-sampling rate
12
analog accelerometer
12
analog
11
data
9
rate wearable
8
wearable analog
8
analog data
8
fast sampling
8

Similar Publications