Enhanced adhesion of functional layers by controlled electrografting of ethylenediamine on ITO for electrochemical immunoassay in microfluidic channel.

Biosens Bioelectron

Program in Nano Science and Technology, Graduate School of Convergence Science and Technology, Seoul National University, Suwon-Si, Gyeonggi-do, 16229, Republic of Korea; Department of Chemistry, Seoul National University, Seoul, 08826, Republic of Korea; Advanced Institute of Convergence Technology

Published: June 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Two-electrode (2E) system of the interdigitated electrode array (IDA), which operates neither reference nor counter electrodes, has great potential to miniaturize multiplex immunoassay in a microfluidic chip for point-of-care testing. However, it is necessary to firmly immobilize the mediator layer on IDA made of indium tin oxide (ITO) which is chemically inert. It is important because the mediator determines the electrochemical potential in the 2E system, but the layer is easy to be detached during the washing processes of immunoassay. Here, we controlled the concentration of ethylenediamine (EDA) to generate a permeable and robust film to adhere to mediators on the ITO IDA chip. Electrooxidation of EDA yielded thin oligomeric ethyleneimine (OEI) film and it provided amine groups for immobilizing the mediator, poly(toluidine blue) (pTB), via common conjugation reaction. Despite repeated flows in the microchannel, which are essential for sensitive immunoassay, the pTB/OEI layer was hardly washed and still remained on the ITO IDA. Myoglobin was measured down to ∼ pg/mL level. Therefore, the ITO IDA modified with the OEI film in the 2E system constituted a stable platform that withstands washing steps for sensitive electrochemical detection in the miniaturized immunoassay.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2023.115201DOI Listing

Publication Analysis

Top Keywords

ito ida
12
immunoassay microfluidic
8
oei film
8
ito
5
immunoassay
5
ida
5
enhanced adhesion
4
adhesion functional
4
functional layers
4
layers controlled
4

Similar Publications

Objectives: This study aimed to clarify the current clinico-epidemiological characteristics of acute pancreatitis (AP) in Japan.

Methods: We conducted a two-stage nationwide survey of patients with AP treated at selected hospitals in 2021, during the COVID-19 pandemic. The first stage estimated the total number of AP patients, while the second collected detailed clinical data.

View Article and Find Full Text PDF

Noninvasive prenatal testing diagnoses fetal aneuploidies in singleton pregnancies with trisomy 21, 18, or 13 accurately. However, clinical data on noninvasive prenatal testing in women with twin or vanishing twin pregnancies are limited. We report on the accuracy and prenatal and neonatal outcomes of noninvasive prenatal testing in twin and vanishing twin pregnancies.

View Article and Find Full Text PDF

Introduction: Intrahepatic cholangiocarcinoma (ICC) is a highly malignant cancer for which surgery is the only curative treatment. The prognosis of ICC is extremely poor, especially in cases of lymph node metastasis (LNM), owing to the high postoperative recurrence rate. Herein, we present a case of advanced ICC with a breast cancer susceptibility gene-2 () mutation, treated with preoperative chemotherapy, including cisplatin, followed by surgery, in which we achieved a pathologic complete response.

View Article and Find Full Text PDF

Utility values of responders and nonresponders are essential inputs in cost-effectiveness studies of radiation therapy for painful bone metastases but, to our knowledge, they have not been reported separately. We sought to determine the utility values of responders and nonresponders using data from a prospective observational study on bone metastases. The original prospective observational study was conducted at 26 centers in Japan.

View Article and Find Full Text PDF