A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Validation of a 0/1 h Algorithm for Rapid Diagnosis of Myocardial Infarction Using a High-Sensitivity Troponin I Assay. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Current guidelines recommend 0/1 h algorithms using high-sensitivity cardiac troponin (hs-cTn) for fast diagnosis of myocardial infarction (MI). Yet, for some assays, existing data is limited. We aimed to evaluate the diagnostic performance and the prognostic value of a rapid 0/1 h algorithm for the Access hs-cTnI assay.

Methods: In consecutive patients presenting with suspected MI, we measured concentrations of Access hs-cTnI at presentation and after 1 hour. Final diagnosis was adjudicated independently by 2 cardiologists. Parameters for diagnostic performance were calculated, applying the recently derived European Society of Cardiology (ESC) 0/1 h algorithm for Access hs-cTnI. Additionally, we assessed the prognostic utility of Access hs-cTnI for the composite end point of all-cause mortality and incident MI at 3 years.

Results: In 1879 patients, 257 non-ST-elevation MIs occurred. Application of the 0/1 h algorithm classified 44.5% as rule-out, 20.3% as rule-in, and triaged 35.1% to the observe group. High rule-out safety was confirmed with a sensitivity of 97.7% (95% CI, 95.0%-99.1%) and a negative predictive value of 99.3% (95% CI, 98.4%-99.7%). Rule-in capacity was moderate with a specificity of 88.0% (95% CI, 86.3%-89.6%) and a positive predictive value of 50.8% (95% CI, 45.7%-55.9%). After exclusion of patients with ST-elevation MI the results showed strong prognostic value, even after adjustment for cardiovascular risk factors and comorbidities, with adjusted hazard ratios of 2.51 (95% CI, 1.56-4.04) in the observe and 3.55 (95% CI, 2.18-5.79) in the rule-in group for the composite end point of all-cause mortality and incident MI at 3 years, compared to ruled-out patients.

Conclusion: The ESC 0/1 h algorithm for Access hs-cTnI allows safe and efficient triage of patients with suspected MI and has strong prognostic utility up to 3 years after the initial evaluation.

Download full-text PDF

Source
http://dx.doi.org/10.1093/clinchem/hvad019DOI Listing

Publication Analysis

Top Keywords

0/1 algorithm
20
access hs-ctni
20
algorithm access
12
diagnosis myocardial
8
myocardial infarction
8
diagnostic performance
8
esc 0/1
8
prognostic utility
8
composite point
8
point all-cause
8

Similar Publications