Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Traction of the ipsilateral leg is usually required to facilitate fracture reduction while operating both-column acetabular fractures. However, it is challenging to maintain constant traction manually during the operation. Herein, we surgically treated such injuries while maintaining traction using an intraoperative limb positioner and investigated the outcomes. This study included 19 patients with both-column acetabular fractures. Surgery was performed after the patient's condition had stabilized, at an average of 10.4 days after injury. The Steinmann pin was transfixed to the distal femur and connected to a traction stirrup; subsequently, the construct was affixed to the limb positioner. A manual traction force was applied through the stirrup and maintained with the limb positioner. Using a modified Stoppa approach combined with the lateral window of the ilioinguinal approach, the fracture was reduced, and plates were applied. Primary union was achieved in all cases at an average of 17.3 weeks. The quality of reduction at the final follow-up was found to be excellent, good, and poor in 10, 8, and 1 patients, respectively. The average Merle d'Aubigné score at the final follow-up was 16.6. Surgical treatment of both-column acetabular fracture using intraoperative traction with a limb positioner yields satisfactory radiological and clinical outcomes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9965046 | PMC |
http://dx.doi.org/10.3390/jcm12041682 | DOI Listing |