98%
921
2 minutes
20
Background: Transition of the CT values from nodule to peripheral normal lung is related to pathological changes and may be a potential indicator for differential diagnosis. This study investigated the significance of the standard deviation (SD) values in the lesion-lung boundary zone when differentiating between benign and neoplastic subsolid nodules (SSNs).
Methods: From January 2012 to July 2021, a total of 229 neoplastic and 84 benign SSNs confirmed by pathological examination were retrospectively and nonconsecutively enrolled in this study. The diagnostic study was not registered with a clinical trial platform, and the study protocol was not published. Computed tomography (CT) values of the ground-glass component (CT1), adjacent normal lung tissue (CT2), and lesion-lung boundary zone (CT3) were measured consecutively. The SD of CT3 was recorded to assess density variability. The CT1, CT2, CT3, and SD values were compared between benign and neoplastic SSNs.
Results: No significant differences in CT1 and CT2 were observed between benign and neoplastic SSNs (each P value >0.05). CT3 (-736.1±51.0 -792.6±73.9; P<0.001) and its SD (135.6±29.6 83.6±20.6; P<0.001) in neoplastic SSNs were significantly higher than those in benign SSNs. Moreover, the SD increased with the invasiveness degree of neoplastic SSNs (r=0.657; P<0.001). The receiver operating characteristic (ROC) curve revealed that the area under the curve was 0.927 (95% CI: 0.896-0.959) when using the SD (cutoff value =106.98) as a factor to distinguish SSNs, which increased to 0.966 (95% CI: 0.934-0.985) when including nodules with a CT1 of ≥-715 Hounsfield units (HU) only (cutoff of SD 109.9, sensitivity 0.930, and specificity 0.914).
Conclusions: The SD as an objective index is valuable for differentiating SSNs, especially for those with a CT1 of ≥-715 HU, which have a higher possibility of neoplasm if the SD is >109.9.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9929397 | PMC |
http://dx.doi.org/10.21037/qims-22-510 | DOI Listing |
Med Image Anal
July 2025
Faculty of Informatics and Data Science, University of Regensburg, Regensburg, Germany; Fraunhofer Institute for Digital Medicine MEVIS, Bremen, Germany. Electronic address:
Accurate medical image segmentation is crucial for enabling automated clinical decision procedures. However, existing supervised deep learning methods for medical image segmentation face significant challenges due to their reliance on extensive labeled training data. To address this limitation, our novel approach introduces a dual-branch transformer network operating on two scales, strategically encoding global contextual dependencies while preserving local information.
View Article and Find Full Text PDFFront Oncol
March 2024
In-Patient Ultrasound Department, The second Affiliated Hospital of Harbin Medical University, Surgeons' Hall, Harbin, China.
Quant Imaging Med Surg
February 2023
Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Background: Transition of the CT values from nodule to peripheral normal lung is related to pathological changes and may be a potential indicator for differential diagnosis. This study investigated the significance of the standard deviation (SD) values in the lesion-lung boundary zone when differentiating between benign and neoplastic subsolid nodules (SSNs).
Methods: From January 2012 to July 2021, a total of 229 neoplastic and 84 benign SSNs confirmed by pathological examination were retrospectively and nonconsecutively enrolled in this study.
J Med Imaging Radiat Sci
March 2022
Radiation Protection Institute (RPI), Ghana Atomic Energy Commission, Accra, Ghana.; Radiological and Non-ionizing Radiation Directorate, Nuclear Regulatory Authority, Accra, Ghana.
Background: Scan length optimization is a method of optimization which ensures that, imaging is performed to cover just the area of interest without unnecessarily exposing structures that would not add value to answer a given clinical question.
Purpose: This study assessed the variability and degree of redundant scan coverages along the z-axis of CT examinations of common indications and the associated radiation dose implications in CT facilities in Ghana for optimization measures to be recommended.
Methods: On reconstructed acquired CT images, the study measured extra distances covered above and below anatomical targets for common indications with calibrated calipers across 25 CT facilities.
Intern Med
December 2021
Division of Pathology, Faculty of Medicine, Tohoku Medical and Pharmaceutical University, Japan.
We report a case of a pulmonary necrotizing sarcoid granulomatosis (NSG)-like lesion possibly associated with coinfection of Mycobacterium avium and Propionibacterium acnes. A solitary nodule in the right middle lobe of the lung was notable for coagulative necrosis with aggregates of sarcoid-like epithelioid granulomas. Small arteries were damaged by granulomas.
View Article and Find Full Text PDF