Article Abstract

Background: A bolus thermodilution-derived index of microcirculatory resistance (IMR) has emerged as the standard for assessing coronary microvascular dysfunction (CMD). Continuous thermodilution has recently been introduced as a tool to quantify absolute coronary flow and microvascular resistance directly. Microvascular resistance reserve (MRR) derived from continuous thermodilution has been proposed as a novel metric of microvascular function, which is independent of epicardial stenoses and myocardial mass.

Aims: We aimed to assess the reproducibility of bolus and continuous thermodilution in assessing coronary microvascular function.

Methods: Patients with angina and non-obstructive coronary artery disease (ANOCA) at angiography were prospectively enrolled. Bolus and continuous intracoronary thermodilution measurements were obtained in duplicate in the left anterior descending artery (LAD). Patients were randomly assigned in a 1:1 ratio to undergo either bolus thermodilution first or continuous thermodilution first.

Results: A total of 102 patients were enrolled. The mean fractional flow reserve (FFR) was 0.86±0.06. Coronary flow reserve (CFR) calculated with continuous thermodilution (CFR) was significantly lower than bolus thermodilution-derived CFR (CFR; 2.63±0.65 vs 3.29±1.17; p<0.001). CFR showed a higher reproducibility than CFR (variability: 12.7±10.4% continuous vs 31.26±24.85% bolus; p<0.001). MRR showed a higher reproducibility than IMR (variability 12.4±10.1% continuous vs 24.2±19.3% bolus; p<0.001). No correlation was found between MRR and IMR (r=0.1, 95% confidence interval: -0.09 to 0.29; p=0.305).

Conclusions: In the assessment of coronary microvascular function, continuous thermodilution demonstrated significantly less variability on repeated measurements than bolus thermodilution.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10242662PMC
http://dx.doi.org/10.4244/EIJ-D-22-00772DOI Listing

Publication Analysis

Top Keywords

continuous thermodilution
24
coronary microvascular
12
reproducibility bolus
8
thermodilution
8
microvascular function
8
bolus thermodilution-derived
8
assessing coronary
8
coronary flow
8
microvascular resistance
8
bolus continuous
8

Similar Publications

Introduction: Coronary microvascular dysfunction (CMD) is increasingly recognized as an important cause of anginal symptoms and poor outcomes. Angina with non-obstructive coronary arteries (ANOCA) is often related to CMD. While physiological assessment of microcirculatory function by coronary bolus thermodilution is widely practiced, more precise and reproducible methodology as well as systematic assessment are necessary.

View Article and Find Full Text PDF

Background: Patients with coronary microvascular dysfunction (CMD) exhibit impaired vasodilatation of the microcirculation. This manifests as reduced microvascular resistance reserve (MRR) due to either increased resting flow (Q; functional CMD) or decreased hyperaemic flow (Q; structural CMD). However, coronary flow is intimately linked to myocardial mass, potentially confounding the interpretation of flow and resistance measurements.

View Article and Find Full Text PDF

Background: Accurate cardiac output assessment is crucial for evaluating hemodynamic status and guiding therapeutic interventions. The fourth generation FloTrac software (the FloTrac method) provides minimally invasive, continuous, and real-time cardiac output estimations. This study aimed to evaluate the accuracy, precision, and trending performance of cardiac output measurements using the FloTrac method compared to bolus thermodilution cardiac output derived from a pulmonary artery catheter (the thermodilution method).

View Article and Find Full Text PDF

Compensatory high resting coronary flow (rCF) is a major determinant of low coronary flow reserve in patients with dilated cardiomyopathy (DCM). We sought to assess if angiography-derived rCF was associated with left ventricle reverse remodeling (LVRR) and clinical outcomes in DCM. Angiography-derived rCF was derived based on TIMI frame count and validated using invasive continuous thermodilution absolute flow (n = 48).

View Article and Find Full Text PDF