Article Abstract

Core temperature monitoring is a research tool used in many studies, though most popularly, heat strain. Ingestible core temperature capsules are a non-invasive and increasingly popular choice for measuring core body temperature, particularly considering the well-established validation of capsule systems. A newer version of the e-Celsius ingestible core temperature capsule has been released since the preceding validation study resulting in a paucity of validated research for the current version of capsules, P022-P, used by researchers. Using a 1:1 ratio of propylene glycol to water in a circulating water bath, and a reference thermometer with resolution and uncertainty of 0.01 °C, we assessed the validity and reliability of 24 P022-P e-Celsius capsules in three groups of eight, at seven temperature plateaus between 35 °C, and 42 °C in a test-retest format. The systematic bias of these capsules across all 3360 measurements was found to be -0.038 °C ± 0.086 °C (p < .001), The TEST-RETEST evaluation revealed excellent reliability by way of a minute overall mean difference of 0.0095 °C ± 0.048 °C (p < .001), and an intraclass correlation coefficient of 1.00 for each of TEST and RETEST conditions. Although quite small, differences in systematic bias across temperature plateaus were observed for both the OVERALL bias-between 0.00066 °C and 0.041°C-and TEST/RETEST bias-between 0.00010 °C and 0.016 °C. We found that the new capsule version outperforms manufacturer guarantees, with half of the systematic bias observed in a validation study of the previous capsule version. Though these capsules tend to slightly underestimate temperature, we find they possess excellent validity and reliability between 35 °C and 42 °C.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtherbio.2023.103486DOI Listing

Publication Analysis

Top Keywords

core temperature
16
validity reliability
8
reliability p022-p
8
version e-celsius
8
temperature capsules
8
ingestible core
8
temperature
6
core
5
capsules
5
assessment validity
4

Similar Publications

The Perseverance rover has explored and sampled igneous and sedimentary rocks within Jezero Crater to characterize early Martian geological processes and habitability and search for potential biosignatures. Upon entering Neretva Vallis, on Jezero Crater's western edge, Perseverance investigated distinctive mudstone and conglomerate outcrops of the Bright Angel formation. Here we report a detailed geological, petrographic and geochemical survey of these rocks and show that organic-carbon-bearing mudstones in the Bright Angel formation contain submillimetre-scale nodules and millimetre-scale reaction fronts enriched in ferrous iron phosphate and sulfide minerals, likely vivianite and greigite, respectively.

View Article and Find Full Text PDF

Among the different forms of hydrotherapy, carbon dioxide (CO) water immersion improves peripheral vasodilation and blood flow compared with tap water immersion; however, the heat stress placed on the body through CO water immersion and the appropriate immersion protocols are uncertain. Therefore, this study aimed to compare the thermoregulatory responses during CO and tap water immersions. The participants were 10 male college baseball players.

View Article and Find Full Text PDF

Nutritionally Relevant Technological Advancements in Professional Cycling.

Int J Sport Nutr Exerc Metab

September 2025

Mary MacKillop Institute for Health Research, Australian Catholic University, Melbourne, VIC, Australia.

Technological innovations can provide cyclists and their support team additional data. These data have potential to improve understanding of performance determinants and could be used to identify and tailor nutritional strategies to improve cycling performance. This potential, however, is dependent on the quality, interpretation, and practical use of the data generated.

View Article and Find Full Text PDF

This study aimed to evaluate outcomes and resource utilization in neonates ≥35 weeks' gestation admitted to the neonatal intensive care unit (NICU) for persistent hypothermia, and to assess the incidence of early-onset sepsis (EOS) as well as the potential benefit of using the Kaiser Permanente EOS calculator for risk stratification.This retrospective study included 161 neonates born ≥35 weeks' gestation admitted to the NICU with persistent hypothermia (core temperature <36.5°C on three separate measurements) at a tertiary care hospital between April 2017 and June 2024.

View Article and Find Full Text PDF

Objective: Exertional heat illness (EHI) remains a challenge for those that exercise in hot and humid environments. Physiological status monitoring is an attractive method for assessing EHI risk and a critical component of recommended layered risk management approaches. While there is consensus that some combination of core body temperature, mean skin temperature, heart rate (HR), and hydration provide an indication of heat strain, a field-feasible metric that correlates to EHI incidence has not been identified.

View Article and Find Full Text PDF