A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

On-Site Remote Monitoring System with NIR Signal-Based Detection of Infectious Disease Virus in Opaque Salivary Samples. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Infectious disease viruses, such as foot-and-mouth disease virus (FMDV), are highly contagious viruses that cause significant socioeconomic damage upon spreading. Developing an on-site diagnostic tool for early clinical detection and real-time surveillance of FMDV outbreaks is essential to prevent the further spread of the disease. However, early diagnosis of FMDV is still challenging due to the limited sensitivity and time-consuming manual result entry of commercial on-site tests for salivary samples. Here, we report a near-infrared (NIR) signal nanoprobe-based highly accurate detection and remote monitoring system toward FMDVs, which automates the analysis and reporting of diagnosis data. The NIR signal lateral flow immunoassay (LFA) was assembled with a nanoprobe with a stable emission intensity at 800 nm, minimizing the interference signal of opaque salivary samples. We investigated the clinical applicability of the NIR signal LFA at biosafety level 3 (BSL-3) laboratories using 147 opaque salivary samples. The NIR signal LFA achieved a 32-fold lower limit of detection (LOD) than a commercial LFA in detecting live FMDVs, including all isolates occurring in the Republic of Korea during 2010-2017. Our results showed that the NIR signal LFA successfully discriminated the FMDV-positive clinical salivary samples from healthy controls with a sensitivity of 96.9%, specificity of 100.0%, and AUC (area under the receiver operator characteristic curve) value of 0.999. Finally, we substantiated the real-time collection of diagnostic results using a customized portable NIR reader at nine different laboratories of government-certified quarantine institutions for foot-and-mouth disease (FMD).

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.2c02818DOI Listing

Publication Analysis

Top Keywords

salivary samples
20
nir signal
20
opaque salivary
12
signal lfa
12
remote monitoring
8
monitoring system
8
infectious disease
8
disease virus
8
foot-and-mouth disease
8
nir
7

Similar Publications