Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Purpose: To determine the efficacy of different fragmentation patterns in femtosecond laser-assisted cataract surgery (FLACS) using Ziemer FEMTO LDV Z8.
Methods: We compared three different types of surgery: conventional cataract surgery (CCS), FLACS with conventional radial slices (named No-Spiderweb), and FLACS with a novel fragmentation pattern (radial slices combined with one or two rings) called "Spiderweb." Visual acuity (VA), nuclear opacity (NO) according to the Lens Opacities Classification System (LOCS lll), effective phacoemulsification time (EPT) and vacuum time were obtained for 845 eyes.
Results: Using FLACS (Spiderweb + No-Spiderweb), EPT was significantly reduced by 26% compared to CCS (FLACS: 2.46 ± 2.60 s; CCS: 3.34 ± 2.89 s; ΔM = - 0.88 s, p < .001). Furthermore, EPT as a function of progression of lens opacity was found to be not only lower in Spiderweb compared to CCS, but also in comparison with No-Spiderweb. At NO3, a significant reduction of 65% in EPT was observed by using Spiderweb compared to CCS (Spiderweb: 0.68 ± 1.23 s; CCS: 1.96 ± 1.53 s; ΔM = - 1.28 s, p <.001). Interestingly, EPT at NO3 was also significantly reduced by 57% in Spiderweb compared to No-Spiderweb (Spiderweb: 0.68 ± 1.23 s; No-Spiderweb: 1.57 ± 1 .59 s; ΔM = - 0.90 s, p <.001). The use of Spiderweb only marginally extends the vacuum time compared to No-Spiderweb by 11 s (Spiderweb: 209.13 ± 35.83 s; No-Spiderweb: 198.35 ± 36.84 s; p = .003) and the postoperative improved VA showed no significant difference among the different types of surgery (all ps ≥ .05).
Conclusion: FLACS significantly reduces EPT compared to CCS. Furthermore, the novel Spiderweb pattern significantly reduces EPT in patients with a cataract of NO3 compared to CCS, but also to FLACS with the existing radial pattern (No-Spiderweb).
Download full-text PDF |
Source |
---|---|