A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Characterizing Spray-Dried Powders through NIR Spectroscopy: Effect of Two Preparation Strategies for Calibration Samples and Comparison of Two Types of NIR Spectrometers. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Emerging portable near infrared (NIR) spectroscopic approaches coupled with data analysis and chemometric techniques provide opportunities for the rapid characterization of spray-dried products and process optimization. This study aimed to enhance the understanding of applying NIR spectroscopy in spray-dried samples by comparing two sample preparation strategies and two spectrometers. Two sets of whey protein-maltodextrin matrixes, one with a protein content gradient and one with a consistent protein content, were spray-dried, and the effect of the two preparation strategies on NIR calibration model development was studied. Secondly, a portable NIR spectrometer (PEAK) was compared with a benchtop NIR spectrometer (CARY) for the moisture analysis of prepared samples. When validating models with the samples with focused protein contents, the best PLS protein models established from the two sample sets had similar performances. When comparing two spectrometers, although CARY outperformed PEAK, PEAK still demonstrated reliable performance for moisture analysis, indicating that it is capable as an inline sensor.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9914283PMC
http://dx.doi.org/10.3390/foods12030467DOI Listing

Publication Analysis

Top Keywords

preparation strategies
12
nir spectroscopy
8
protein content
8
nir spectrometer
8
moisture analysis
8
nir
7
characterizing spray-dried
4
spray-dried powders
4
powders nir
4
spectroscopy preparation
4

Similar Publications