98%
921
2 minutes
20
Accelerator mass spectrometry (AMS) is one of the most sensitive techniques used to measure the long-lived actinides. This is particularly of interest for determination of ultra-trace transuranium nuclides and their isotopic fingerprints for nuclear forensics. In this work, a new method was developed for simultaneous determination of transuranium nuclides (Np, Pu, Am, and Cm isotopes) by using 300 kV AMS after a sequential chemical separation of each group of actinides. Pu and Am were utilized as tracers for Np/Pu and Am/Cm yield monitoring. The results show that the chemical behaviors of Np and Pu on the TK200 column and those of Am and Cm on the DGA column were very consistent in 8-9 mol/L of HNO and 0.015-0.03 mol/L of NaNO media during the radiochemical separation. The AMS detection efficiencies for transuranium nuclides were also evaluated. The detection limits for all radionuclides are below femtogram level and even in attogram level for Pu and Cm isotopes. The established method has been successfully applied to accurately measure various transuranium nuclides in a single actinide radionuclide solution, demonstrating its feasibility for nuclear forensic investigation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.2c04544 | DOI Listing |
Anal Chem
February 2024
Frontiers Science Center for Rare Isotopes, Lanzhou University, Lanzhou 730000, P. R. China.
The urine bioassay method for transuranium nuclides (Np, Pu, Am, and Cm) is needed to quickly assess the potential internal contamination in emergency situations. However, in the case that the analysis of multiple radionuclides is required in the same sample, time-consuming/tedious sequential analytical procedures using multiple chromatographic separation resins would have to be employed for the separation of every single radionuclide. In this work, a rapid method for the simultaneous determination of transuranium nuclides in urine was developed by using triple quadrupole inductively coupled plasma mass spectrometry (ICP-MS/MS) combined with a single DGA resin column.
View Article and Find Full Text PDFAnal Chem
February 2023
Frontiers Science Center for Rare Isotopes, Lanzhou University, Lanzhou 730000, P. R. China.
Accelerator mass spectrometry (AMS) is one of the most sensitive techniques used to measure the long-lived actinides. This is particularly of interest for determination of ultra-trace transuranium nuclides and their isotopic fingerprints for nuclear forensics. In this work, a new method was developed for simultaneous determination of transuranium nuclides (Np, Pu, Am, and Cm isotopes) by using 300 kV AMS after a sequential chemical separation of each group of actinides.
View Article and Find Full Text PDFEur Phys J A Hadron Nucl
October 2022
Max-Planck-Institut für Kernphysik, 69117 Heidelberg, Germany.
The absolute atomic mass of Pb has been determined with a fractional uncertainty of by measuring the cyclotron-frequency ratio of Pb to Xe with the high-precision Penning-trap mass spectrometer Pentatrap and computing the binding energies and of the missing 41 and 26 atomic electrons, respectively, with the fully relativistic multi-configuration Dirac-Hartree-Fock (MCDHF) method. has been measured with a relative precision of . and have been computed with an uncertainty of 9.
View Article and Find Full Text PDFAnal Chem
September 2016
European Commission, Joint Research Centre, Institute for Transuranium Elements, P.O. Box 2340, D-76125 Karlsruhe, Germany.
Employing a commercial high-resolution inductively coupled plasma optical emission spectrometry (HR-ICP-OES) instrument, an innovative analytical procedure for the accurate determination of the production age of various Pu materials (Pu powder, cardiac pacemaker battery, (242)Cm heat source, etc.) was developed and validated. This undertaking was based on the fact that the α decay of (238)Pu present in the investigated samples produced (234)U and both mother and daughter could be identified unequivocally using HR-ICP-OES.
View Article and Find Full Text PDFJ Radioanal Nucl Chem
June 2015
European Commission, Joint Research Centre (JRC), Institute for Reference Materials and Measurements, Retieseweg 111, 2440 Geel, Belgium.
The paper describes the preparation and production of the reference materials, IRMM-1000a and IRMM-1000b, certified for the production date based on the Th/U radiochronometer in compliance with ISO Guide 34:2009. The production date of the reference materials corresponds to the last separation of Th from U, i.e.
View Article and Find Full Text PDF