Article Abstract

Objective: Proximal endovascular reintervention after prior endovascular aortic repair (EVAR) or open abdominal aortic aneurysm repair (OR) can be challenging due to the short distance to the visceral branches. We present a novel solution to allow the use of the commercially available ZFEN device using a double-barrel, kissing-limb technique.

Methods: Patients who underwent fenestrated repair for proximal failure after EVAR or OR were identified. The ZFEN device is deployed above the prior graft flow divider. Once the visceral branches are secured, kissing limbs are used to connect with the prior graft limbs. The distal diameter of the standard ZFEN is 24 mm, accommodating two 20 mm components according to the formula 2πD = πD + 2D.

Results: Of 235 patients who underwent repair using ZFEN from 2012 to 2021 at a single institution, 28 were treated for proximal failure of prior repairs, with 13 treated using the double-barrel technique (8 EVAR, 5 OR). The distance from the flow divider to the lowest renal artery was 67 ± 24.4 mm (range, 39-128 mm), and the distance to the superior mesenteric artery (SMA) was 87 ± 30.5 mm (range, 60-164 mm). Technical success was 100%. Seven patients had standard ZFEN builds (2 renal small fenestrations, SMA large fen/scallop). The minimum distance to the lowest renal artery and SMA to accommodate a standard ZFEN build was 56 and 60 mm, respectively. Four patients required adjunctive snorkel grafts and two required laser fenestrations. Two patients had gutter leaks at 1 month that self-resolved; one patient developed a late type 1a endoleak. Freedom from reintervention was 90%, 72%, and 48% at 1, 2, and 3 years, respectively.

Conclusions: This double-barrel technique allows for distal seal of commercial ZFEN devices into prior open or endovascular repairs with good technical success. Long-term outcomes remain to be quantified.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9898739PMC
http://dx.doi.org/10.1016/j.jvscit.2022.101091DOI Listing

Publication Analysis

Top Keywords

double-barrel technique
12
standard zfen
12
open endovascular
8
abdominal aortic
8
aortic aneurysm
8
aneurysm repair
8
visceral branches
8
zfen device
8
patients underwent
8
proximal failure
8

Similar Publications

Introduction: The goal of using ultrasound-guided (USG) arthrocentesis is to reduce number of needle insertion attempts, which is hypothesized to reduce procedure time, postoperative pain, and consequently, limitation in range of motion.

Purpose: The objective of this study was to compare the therapeutic and operative efficiency of USG Single-Puncture Arthrocentesis (SPA) Type 2 and SPA Type 2 arthrocentesis without ultrasound guidance in the treatment of temporomandibular joint (TMJ) internal derangement (ID) "disc displacement without reduction (DDWOR)."

Materials And Methods: A double-blinded prospective randomized clinical trial (RCT) was conducted from December 2022 to December 2023 at Ain Shams University Hospital.

View Article and Find Full Text PDF

Blood blister-like aneurysms (BBAs) are small, fragile vascular lesions that develop on the walls of the supraclinoid internal carotid artery. The absence of a defined aneurysmal neck presents challenges in both surgical and endovascular management. The hybrid operating angiosuite (HOA), which integrates microsurgical and endovascular techniques, provides a potential approach for treating these complex aneurysms.

View Article and Find Full Text PDF

The authors present a novel approach using a vascularized double-barrel fibula flap combined with an intramedullary nail (IMN) to reconstruct critical-size segmental tibial defects. Current methods, such as bone transport or induced membrane techniques, require multiple procedures and are associated with high complication rates and delayed load bearing. We present the case of a 44-year-old man with nonunion and chronic osteomyelitis of the left tibia, who underwent reconstruction with a contralateral double strut free fibula flap, placement of IMN, and cancellous bone grafting.

View Article and Find Full Text PDF

The medical management and non-transplant surgical options for children with short bowel syndrome (SBS)are maximized as first-line treatments. The purpose of this review is to summarize the currently available evidence and new management strategies in children with SBS. A systematic review of the literature was conducted on data from the last four years, focusing on both the effectiveness and safety of intestinal lengthening procedures, as well as frameworks for the prevention of complications and the achievement of enteral autonomy.

View Article and Find Full Text PDF

Capacitance compensation on a double-barrel nanopipette for improving current detection of scanning ion conductance microscopy.

Ultramicroscopy

July 2025

Department of Pathology and Anatomical Science, Graduate School of Medical and Dental Science, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.

We developed a method to improve the current-detection response of scanning ion conduction microscopy (SICM) using a double-barrel nanopipette. By detecting the difference between the two signals from each channel, capacitive currents can be canceled out, resulting in an improved ion current detection response and reduced imaging time in bias-modulated scanning ion conductance microscopy operated with AC bias voltages (BM-SICM). Furthermore, this method can reduce the synchronized capacitive current noise of two adjacent channels of a double-barrel nanopipette by canceling each other via a differential operation.

View Article and Find Full Text PDF