A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Alignment and use of microbeam with full-field x-ray microscopes. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Demonstration tests of the alignment of Fresnel zone plate focusing optics using a full-field x-ray microscope and microbeam x-ray diffraction measurements combined with the full-field x-ray microscope were performed. It was confirmed that the full-field x-ray microscope enables direct two-dimensional observation of a microbeam with sub-micrometer spatial resolution. This allowed visualization of the misalignment of the focusing optics, resulting in accurate alignment of the optics within a short time. In addition, the microscope could be used to observe the sample as well as the microbeam, which enabled clarification of the position and two-dimensional shape of the microbeam on the sample. This realized a measurement procedure that a 100-μm-size sample was imaged with sub-micrometer spatial resolution, and then, microbeam-use measurements were performed for only the region of interest determined by the microscope, which has been difficult with conventional microbeam applications. The combination of observations by a full-field x-ray microscope and measurements using a microbeam is expected to open a new style of measurement.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0123780DOI Listing

Publication Analysis

Top Keywords

full-field x-ray
20
x-ray microscope
16
focusing optics
8
sub-micrometer spatial
8
spatial resolution
8
x-ray
6
microscope
6
microbeam
6
full-field
5
alignment microbeam
4

Similar Publications