Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Purpose: This research note illustrates the effects of video data with nonsquare pixels on the pixel-based measures obtained from videofluoroscopic swallow studies (VFSS).
Method: Six pixel-based distance and area measures were obtained from two different videoflouroscopic study units; both yielding videos with nonsquare pixels with different pixel aspect ratios (PARs). The swallowing measures were obtained from the original VFSS videos and from the videos after their pixels were squared.
Results: The results demonstrated significant multivariate effects both in video type (original vs. squared) and in the interaction between video type and sample (two video recordings of different patients, different PARs, and opposing tilt angles of the external reference). A wide range of variabilities was observed on the pixel-based measures between original and squared videos with the percent deviation ranging from 0.1% to 9.1% with the maximum effect size of 7.43.
Conclusions: This research note demonstrates the effect of disregarding PAR to distance and area pixel-based parameters. In addition, we present a multilevel roadmap to prevent possible measurement errors that could occur. At the planning stage, the PAR of video source should be identified, and, at the analyses stage, video data should be prescaled prior to analysis with PAR-unaware software. No methodology in prior absolute or relative pixel-based studies reports adjustment to the PAR prior to measurements nor identify the PAR as a possible source of variation within the literature. Addressing PAR will improve the precision and stability of pixel-based VFSS findings and improve comparability within and across clinical and research settings.
Supplemental Material: https://doi.org/10.23641/asha.21957134.
Download full-text PDF |
Source |
---|---|