A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Technical notes on peripheral refraction, peripheral eye length and retinal shape determination. | LitMetric

Technical notes on peripheral refraction, peripheral eye length and retinal shape determination.

Ophthalmic Physiol Opt

Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, Antwerp University, Wilrijk, Belgium.

Published: May 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To give an overview of the misconceptions and potential artefacts associated with measuring peripheral refractive error and eye length, the use of these measures to determine the retinal shape and their links to myopia development. Several issues were identified: the relationship between peripheral refractive error and myopia development, inferring the retinal shape from peripheral refraction or eye length patterns, artefacts and accuracy when measuring peripheral eye length using an optical biometer.

Methods: A theory was developed to investigate the influence of artefacts in measuring peripheral eye length and on using peripheral eye length to make inferences about retinal shape.

Results: When determining peripheral axial length, disregarding the need to realign instruments with mounted targets can lead to incorrect field angles and positions of mounted targets by more than 10% for targets placed close to the eye. Peripheral eye length is not a good indicator of the effects of myopia or of treatment for myopia development because eyes of different lengths but with the same retinal shape would be interpreted as having different retinal shapes; the measurement leads to overestimates of changes in retinal curvature as myopia increases. Determining peripheral eye length as a function of estimated retinal height rather than field angle will halve the magnitude of the artefact. The artefact resulting from the peripheral use of biometers with an on-axis calibration is modest and can be ignored.

Conclusion: There are significant issues with peripheral measurements of the refractive error and eye length that must be considered when interpreting these data for myopia research. Some of these issues can be mitigated, while others require further investigation.

Download full-text PDF

Source
http://dx.doi.org/10.1111/opo.13097DOI Listing

Publication Analysis

Top Keywords

eye length
36
peripheral eye
24
retinal shape
16
peripheral
13
measuring peripheral
12
refractive error
12
myopia development
12
eye
10
length
10
peripheral refraction
8

Similar Publications