A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Measurement of Force and Intramuscular Pressure Changes Related to Thrust Spinal Manipulation in an In Vivo Animal Model. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Current knowledge regarding biomechanical in vivo deep tissue measures related to spinal manipulation remain somewhat limited. More in vivo animal studies are needed to better understand the effects viscoelastic tissue properties (i.e., dampening) have on applied spinal manipulation forces. This new knowledge may eventually help to determine whether positive clinical outcomes are associated with particular force thresholds reaching superficial and/or deep spinal tissues. A computer-controlled feedback motor and a modified Activator V device with a dynamic load cell attached were used to deliver thrust spinal manipulations at various magnitudes to the L7 spinous process in deeply anesthetized animals. Miniature pressure catheters (Millar SPR-1000) were inserted unilaterally into superficial and deep multifidi muscles. Measurements of applied mechanical forces and superficial/deep multifidi intramuscular pressure changes were recorded during spinal manipulations delivered in vivo. Manipulative forces and net changes in intramuscular pressures reaching deep spinal tissues are greatly diminished by viscoelastic properties of in vivo tissues, which could have possible clinical safety and/or mechanistic implications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9855381PMC
http://dx.doi.org/10.3390/biology12010062DOI Listing

Publication Analysis

Top Keywords

spinal manipulation
12
intramuscular pressure
8
pressure changes
8
thrust spinal
8
vivo animal
8
deep spinal
8
spinal tissues
8
spinal manipulations
8
spinal
7
vivo
5

Similar Publications