A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Feasibility of a silicone vascular phantom replicating real arterial contrast filling dynamics on cerebral angiography: An in-vitro pilot study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Some cerebral arterial silicone phantoms have been used in preclinical evaluations. However, typical silicone-based phantoms are limited in their capacity to reproduce real contrast filling dynamics of the human cerebral artery. This study aimed to develop a cerebral arterial silicone phantom to analyze the feasibility of real contrast filling dynamics. The fluid circulation phantom system consisted of a cerebral arterial silicone phantom without or with additional devices, a pump, an injection system, a pressure-monitoring system, a constant-temperature bath, and a venous drainage container. Vascular resistance was reproduced with a plastic cistern only or a plastic cistern filled with a sponge pad. Three phantom groups were constructed as follows: a) the cerebral arterial silicone phantom used as the control group (type A), b) phantom with the incorporated plastic cistern (type B), and c) phantom with the incorporated plastic cistern filled with a sponge pad (type C). The contrast concentration-time curve patterns of the three groups obtained from digital subtraction angiography (DSA) were compared. Consequently, the DSA pattern of the type C phantom was the most similar to that obtained from the control group as the reference data, which showed the broadest full-width-at-half-maximum and the area under the curve values and the highest maximum contrast concentration. In conclusion, we could emulate the arterial contrast filling dynamics of clinical cerebral angiography by applying a small cistern filled with a sponge pad at the drainage side of the phantom.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9844885PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0280395PLOS

Publication Analysis

Top Keywords

contrast filling
16
filling dynamics
16
cerebral arterial
16
arterial silicone
16
plastic cistern
16
silicone phantom
12
cistern filled
12
filled sponge
12
sponge pad
12
type phantom
12

Similar Publications